![Q-Pumps QTS-M08 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/q-pumps/qts-m08/qts-m08_operation-and-maintenance-manual_3081404013.webp)
13
OPERATION AND MAINTENANCE MANUAL
QTS SERIES
Twin Screw Positive Displacement Pump
QTS-M
08
Proceed to verify the angular alignment by measuring the space between the couplings in
both vertical and horizontal direction. The measured space has to be equal at both sides of the
coupling use shims in the pump base or motor base if needed. Proceed to align the pump and
drive parallel to the axis of rotation. Use a straight edge in both top and side of the couplings to
guarantee parallelism.
Pump Rotation
Check the direction of rotation prior to connecting the pump to the drive.
ALINEACION PARALELA
ALINEACION ANGULAR
VISTA SUPERIOR
VISTA LATERAL
B
A
S
E
A
L
IG
N
M
E
NT