| +1 (866) 203-8397
Pyxis LT-635 User Manual
8
Submersed Installation with Lifting Ring:
The LT-635 sensor comes equipped with a lifting ring which
allows the sensor to be lifted and lowered using a user provided chain or cable. This method of installation
enables use of the LT-635 in clarifier or thickener sludge bed depth profiling. Users may mark
measurement increments on the user provided lifting chain/cable and the LT-635 sensor may be slowly
lowered into the clarifier/thickener. When a drastic increase in suspended solids measurement is
observed, the sensor has been exposed to the clarifier/thickener sludge bed. The lowered distance of the
sensor to this observed TSS measurement change as indicated on the marked chain/cable can be used as
a reference of the clarifier/thickener supernatant (clean water). This value when subtracted from the total
clarifier/thickener height may be used as a reference to the sludge bed depth. For this method of
installation and use, please refer to Figure 3. For sensor replacement and maintenance, users only need
to lift the chain or cable and LT-635 Sensor vertically (upwards).
Lifting Ring
Figure 3 - Submersed Installation Using the Lifting Ring
Reference ID
Name
1
Retention Chain / Cable
2
Sensor Output Cable
3
LT-635 Suspended Solids Sensor
2
1
3
Содержание LT-635