Installation
Submersed Fixed Installation with MA-120-C
: The LT-635 may be installed in a submersed/fixed
application using the MA-120-C Submersion Adapter Mounting Bracket (P/N: 50700A11). The LT-635
sensor should be installed as outlined in Figure 2 and 2A. For installation, the MA-120-C bracket
should permanently mounted in a fixed position for easy access to the LT-635 sensor and piping.
For sensor replacement and maintenance, users only need to lift (vertically/upwards) the sliding
block and conduit with the mounted sensor from MA-120-C bracket. Please note the LT-635
outer diameter is ¾ - inch NPT. A ¾ to 1-inch NPT bushing is required for installation.
Figure 2
–
MA-120-C Submersion Adapter Mounting Bracket
MA-120-C
SS-304 Pipe (1-inch NPT)
Reducing Coupler (1-inch to 3/4 -inch FNPT
LT-635 ( ¾-inch MNPT
figure 2A - Installation Using MA-120-C Submersion Bracket with Piping