10.6 Digital
Communicators
The Digital communicators may be programmed to switch between 0 to 12 volts or 12 to 0 volts depending upon how the
system options are programmed.
10.7
Auxiliary and Push To Set
Auxiliary Positive (+)
Auxiliary Negative (-)
Push To Set
The Push To Set or door bell switch must be a normally open contact switch.
10.8 Tamper
Tamper 1
Spare
The Atlas has a dedicated tamper connection. The two outer connections should be used for tamper feed and return and
the middle connections used for tamper loop.
10.9
Tamper Connection for Bell Box's with Negative Removed Tamper
Bell Box
Negative Tamper
KTR
KT
Panel
Tamper
If the panel is to be connected to a bell box with negative (-) removed tamper, the above connections must be made.
Note: Select Global Tamper Negative Return in System Option 21 when wired this way.
10.10 Shock
Sensors
Wiring for shock sensor re-set.
+
-
+
-
Aux +
Shock Sensor
Shock Sensor
Up to 20 shock sensors wired in parallel, may be used with the Atlas panel (on output 1 only).
Page 24