15
COMMUNICATION PROGRAMMING
Programmable Outputs
Programmable Output 1 Default Off
Programmable Output 2
Default Off
System Option 1
1 Default End Of Line
2 Default User log Reset Disabled
3 Default Tone Dial
4 Default Internal Sounder Only
System Option 2
1 Default 24 Hour Test Dial
2 Default No Dial-in
3 BSIA Test Dial No
4 Default Audible P.A.
System Option 3
1 Default Engineer Power Up NVM Reset
2 Default Engineer System Reset Disabled
3 Default User Omit Enabled
4 Default Door Chime On PTS Enabled
System Option 4
1 Default Anti Code Reset Disabled
2 Display Open Zones Off
3 No Alarm On Line Fail - STU
4 No Alarm On Line Fail - PC
System Option 5
1 Default Alarm Digi Active Low
2 Default P.A. Active Low
3 Default Fire Active Low
4 Default Confirmed Digi Active Low
System Option 6
1 Default Abort Low
2 Default Open High
3 Wide Handshake Filters
4 Standard Handshake Filters
System Option 7
1 Alarm Restoral Reporting Off
2 P.A. Restoral Reporting Off
3 Fire Restoral Reporting Off
4 Confirmed Alarm Restoral Reporting Off
System Option 8
1 Abort Restoral Reporting Off
2
Spare
3
Spare
Rins163 Issue 9