background image

Fixing instructions
(Please read carefully before attempting installation.)
Rear Casing
1. 
Select a suitable location with a sound flat surface. Using the case as a template, mark the position
of the four fixing holes (A) on the surface.
2. Drill and plug the fixing holes to suit fixing screws (E) as supplied.
3. Locate the thicker 6mm thick sealing gasket (B) on the rear face of the case before positioning the
case over the fixing holes (A).
4. Secure the case to the surface using suitable fixing screws (E) (as supplied).

Keypad to Casing
5
. When making the electrical connections to the connector block care should be taken not to damage
the thin sealing gasket (C) fixed to the front face of the rear case. [For connection details see section iii)
of this manual].
6. Fix the keypad to the case using the thread forming security screws 
(D) as supplied. (Please ensure the nylon sealing washers are located
beneath the head of the security screws (D). Please note a special key
is provided for tightening these screws.
7. Check the installation to ensure gaskets are in place 
and compressed evenly around the perimeter of the case.

Note: On rough or uneven surfaces it may be
necessary to apply a bead of silicone
sealant around the inner face of the case
at the point where it meets the
mounting surface. Where
this method of sealing is
necessary the thicker
sealing gasket (B) 
must not be fitted.

1

3

2

6

5

4

7

9

8

0

ii) INSTALLATION INSTRUCTIONS

Storm AXS Code Master keypads convert codes entered via the keypad into industry standard 26 bit or
32 bit (Weigand) data. They are suitable for use as a replacement for, or in conjunction with, most
standard card readers that form part of an integrated access control / security system. All keypads in the
range will accept either a +5V or +12V DC supply. Door / system status is indicated by a high intensity
LED light source and an audible sounder. The sounder can be deselected for installations where audible
signals would be disruptive or considered an annoyance. Storm AXS Code Master keypads are specified
to survive in different service environments ranging form exposed, unsupervised public locations to
general service outdoor / indoor installations. All Storm AXS Code Master keypads are dimensionally and
electrically interchangeable. This allows users, entering codes at all outdoor or indoor access points, to
establish and maintain familiarity with the keypad features.

t

m

r

o

Secure Keypads 
for access control

®

i) INTRODUCTION 

Code Master

A

B

C

D

E

• Two protection levels

– anti vandal keypad for unsupervised   

public, outdoor locations

– robust keypad for general 

outdoor / indoor locations

• 26 bit or 32 bit data output

• Selectable ‘keypress’ audible tone
• Selectable ‘code accepted’ audible tone
• LED and audible tone status indication
• Re5V or +12V DC supply
• All weather resistant

WES-MAN ISS.2