background image

 

 

       

 

Copyright Pyroban Ltd.                                                                              Issue 1 Page 3 of 32 

Part number PM1083ENG 

 

I

NTRODUCTION

 

This manual contains instructions on Installing, Operating and Servicing Pyroban’s Gascheka 
duo product. 

 

Gascheka duo offers real time flammable gas detection with automatic equipment shutdown. 
 

 

IMPORTANT INFORMATION 

Adding Gascheka duo to equipment will not change the hazardous area rating of the 

equipment on which it is installed. Further modification, testing and certification by a 

recognized testing laboratory will be required to change the equipment’s hazardous 

area rating. 

 

 

 

IMPORTANT INFORMATION 

The Pyroban Pellistor Gas Sensing Head has a high level of poison resistance, but it 
may be irreversibly damaged by certain materials. These materials will increase the 
replacement frequency of the Gas Sensing Head. 

 

Materials that might damage the Pellistor Gas Sensing Head include: 

 

Organic silicon containing compounds such as silicone fluids and greases. 

 

Organic lead containing compounds 

 

Organic phosphorous containing compounds 

 

The Pyroban Infrared Gas Sensing Head is not affected by these materials.  

The Pellistor and Infrared Gas Sensing Head will not detect the above materials. 

 

 

 

IMPORTANT INFORMATION 

Operation of the Pyroban Pellistor Gas Sensing Head may be temporarily impaired by 
other materials. Normal operation may be resumed after a period of operation in clean 
air. 

Material that might temporarily impair proper functioning of the Pellistor Gas Sensing Head 
includes: 

 

Hydrogen sulphide and organic sulphur containing compounds 

 

Halogenated hydrocarbons such as refrigerants 

 

The Pyroban Infrared Gas Sensing Head is not affected by these materials 

The Pellistor and Infrared Gas Sensing Head will not detect the above materials. 

Содержание Gascheka duo System 5000

Страница 1: ...nstructions COPYRIGHT 2017 All rights reserved No parts of this manual may be reproduced stored in a retrieval system or transmitted in any form or by any other means electronic mechanical photocopyin...

Страница 2: ...allas keys 11 Operating the Vehicle 12 De activating the System 13 Explanation of Vehicle Shutdown and Control Unit Warnings 135 Installation 15 Installation Diagram 15 Preparation 16 Tools Required f...

Страница 3: ...frequency of the Gas Sensing Head Materials that might damage the Pellistor Gas Sensing Head include Organic silicon containing compounds such as silicone fluids and greases Organic lead containing c...

Страница 4: ...on For any questions or concerns about this or any other Pyroban products or services please do not hesitate to contact us Pyroban Ltd Endeavour Works Dolphin Road Shoreham by Sea West Sussex BN43 6QG...

Страница 5: ...completed Gas calibration is performed using 0 5 propane in air contained in a 0 5 litre cylinder which requires periodic replacement This gas mixture is non flammable A set of driver and supervisor k...

Страница 6: ...ol Unit The Control Unit receives the gas sensing head signal and controls the shutdown function of the Relay Unit The Control Unit also displays the various warning and shutdown modes to the operator...

Страница 7: ...Test Gas Cylinder contains a non flammable mixture of propane in air which is used to verify correct operation of the Gas Sensing Head Electronic button key The Electronic Button Keys Dallas keys are...

Страница 8: ...ad See recommended spares The Pyroban standard limited product warranty for Gascheka duo does not cover the Gas Sensing Head in environments where the materials that might damage the sensing head are...

Страница 9: ...se F3 F4 Fuse element T2 0A 5x20mm The current rating of the relays is 2A maximum Install gas sensing heads between 20 and 60 to the horizontal Warning The voltage selection link in the Relay unit mus...

Страница 10: ...by the vehicle manufacturer 2 Check the general condition of the vehicle and Pyroban equipment as defined in the Routine Servicing section of this manual 3 Ensure the valve on the Pyroban test gas cyl...

Страница 11: ...pellistor 4 Start up is complete when you see a green tick on the Control module If the gas test is failed refer to the Trouble Shooting section Use of Dallas keys The green or blue keys are used to...

Страница 12: ...inhibit all vehicle functions immediately or in some cases critical functions e g power steering may be preserved for a period of time so that the vehicle may be brought to a controlled stop A time de...

Страница 13: ...ionary and properly secured according to the vehicle hand book From Drive mode illuminated place the green or blue electronic button key onto the receptor on the Control module The Drive mode indicato...

Страница 14: ...ing to activate Vehicle is still operational Vehicle should be driven safely from the gas contaminated area Inform the Person in Authority DO NOT re enter the gas contaminated area until authorized to...

Страница 15: ...Copyright Pyroban Ltd Issue 1 Page 15 of 32 Part number PM1083ENG INSTALLATION Installation Diagram...

Страница 16: ...Relay Unit to Control Unit The remaining of the cable is non incendive but should be routed within the confines of the vehicle or mechanically protected to give reliable long term operation Control Un...

Страница 17: ...Loosely mount the Control Unit support bracket install the Gas Head Lead to the Control Unit and secure Lead to the bracket d Fit the Control Unit Support Bracket 300814200 Gas Sensing Head a Gas sen...

Страница 18: ...t in the environment the Pellistor Gas Sensing Head will not be covered by Pyroban warranty protection Test Gas Cylinder 1 Position the gas bottle where the pressure gauge is visible and where the veh...

Страница 19: ...two voltage versions 815859 12V for use with 12V vehicles 815859 for use with 24V to 80V vehicles Warning Use of 815859 12V on voltages above 12V will result in permanent damage to the Relay unit Note...

Страница 20: ...nal J5 and follow the guidelines on the connection diagram The period of delay on this shutdown is installer settable to a maximum value of 25 seconds using the DIP switch on the PCB Refer to the conn...

Страница 21: ...xcess must be coiled and tied to the vehicle away from any moving parts within the confines of the vehicle 15 Connect the test gas pipe from the regulator on the test gas cylinder to the Gas Sensing H...

Страница 22: ...valve on the bottle Disconnect the test gas pipe from the Gas Sensing Head 19 Place plastic bag bag that contains labels can be used over the Gas Sensing Head 20 Insert the test gas pipe into the pla...

Страница 23: ...e driver s sight Add Job Identification number to label if required 26 Peel the protective backing off the Isolator Switch Sticker and position it adjacent to switch on the equipment Where delayed shu...

Страница 24: ...nd that all fixings are secure Replacement of Fuses Fuses must only be replaced with the correct type as specified below Fuse Location Type F1 Main power fuse located in Relay Unit T3 15A 5 20 mm HBC...

Страница 25: ...failure on the 7 segment status indicator The table below shows the types of failure and possible corrective actions 7 segment status indicator Type of fault Corrective action in each case power the...

Страница 26: ...ban Ltd Issue 1 Page 26 of 32 Part number PM1083ENG Denotes that indicator is flashing OK Fault refer to manual Gas test phase 1 2 or 3 Flammable material in atmosphere 7 segment status indicator Soun...

Страница 27: ...isor Dallas key on to the key receptor on the Control module Restart Gascheka duo in the normal way using either the green or blue key Automated gas test failure Investigation required Pyroban equipme...

Страница 28: ...st will be passed and the Green tick illuminated so that the vehicle may be driven however the corresponding Test indicator will remain flashing Urgent servicing is required The Person in Authority mu...

Страница 29: ...W max Humidity 15 to 90 RH non condensing Ambient Temperature The system is specified from 20 C to 50 C The System should be protected from high intensity solar radiation at high ambient temperatures...

Страница 30: ...813 Gas Bottle 0 5l 450539 Gas tube 500886 Gas Sensing Head lead Part No Length m 804993 3 804993 5 804993 10 Kit Selected 804993 1 804993 15 804993 30 Option Power lead Part No Length m 804990 3 Stan...

Страница 31: ...tone 36 31 Butane 31 12 Cyclohexane 41 22 Di methyl ethylene 33 89 DI Ethyl Ether 39 10 Ethane 21 79 Ethanol 28 24 Ethyl Acetate 41 22 Ethylene oxide 31 12 Ethylene 21 79 Heptane 43 57 Hexane 39 10 Is...

Страница 32: ...VE RESPONSE Material LEL shutdown Cyclohexane 28 4 Ethanol 20 6 Ethyl acetate 58 8 Kerosene 53 4 Methanol 22 7 Isopropanol 40 4 n Heptane 31 2 n Propanol 36 4 n Propyl acetate 41 0 Butane 30 5 Isobuta...