6
Setting the activation time in
monostable mode
In monostable mode, it is possible to program the relay on time in the
range of ~ 1 – 255s (~ 4min 15s). To program the time you need a transmitter
with a key assigned to the channel in which the change is to take place. To do
this:
1. Press and hold the
learning
button for 5 – 8s.
2. All the LEDs will start blinking, and after a while they will start blinking
much faster – release the
learning
button.
3. Releasing the
learning
button will cause all
red
LEDs to flash. One blink
corresponds to ~1s.
4. After the required time has elapsed, press in the transmitter the key
corresponding to the channel to which the new relay activation time
should be assigned in the monostable mode.
5. Successful saving will be confirmed by blinking of all
red
LEDs three
times.
6. Leaving the receiver in the countdown mode will lead to the
countdown of 255s, and then all the LEDs will be lit for ~4 min –
pressing the key during this time will program the maximum time
(255s) to the channel assigned to the key. If no key is pressed before
the end of ~4 minutes, the receiver will exit the time programming
mode without making any changes.
10