6. ACCESS LOCK
6.1. SWITCHING THE ACCESS LOCK ON
5.3. MEASUREMENT FUNCTIONS
5.2. INDIVIDUAL PARAMETERS
5.4. SCENES AND CHASERS PROGRAMMING
6
1. - internal dimmer temperature.
2. , , - power supply voltage.
1. - DMX address. Chosen from the 1 - 512 range.
2. - control curve choice. There are 8 options to choose from:
- linear,
- switchable,
- inverted,
- logarithmic,
- exponential,
... - for neon lamps control.
3. -limit. Limits the output voltage in the range from 50 - 230 V.
1. ... - scenes programming
... - the number of the edited channel
... - channel value described in %.
2. - programmable chaser
... - numbers of the edited scenes
... - numbers of the edited channel
... - the value of the chosen channel described in %
- chaser speed in the range 1 - 32
- switching on / off the crossfade function.
3. - factory-defined chaser
- chaser speed in the range 1 - 32
- switching on / off the crossfade function.
Because of a great number of possibilities when defining the dimmer functions, all introduced
changes can be protected with a code (number in a range from 0 - 255). The position of the
main menu will also be hidden.
1. In the basic position of the display (DMX address of the first channel) push and hold TEST
button, push shortly NEXT button and release TEST button - will show.
2. Push ENTER button - inscription will show.
3. Push ENTER button again - the last set code will show.
4. Set new code using "PREV" and "NEXT" buttons (or leave the previous one) and confirm
changes by pressing the ENTER button.
Содержание PX091
Страница 1: ...MANUAL AC Dimmer 12 x 1200 W PX091 R...