5
5. PROGRAMMABLE PARAMETERS
5.1. GROUP PARAMETERS
1. - DMX address. It is chosen from the 1 - 501 range (when 501 address is chosen, channel
no. 12 has the address 512).
2. - control curve choice. There are 8 options to choose from:
- linear,
- switchable,
- inverted,
- logarithmic,
- exponential,
... - for neon lamps control.
3. - limit. Limiting the output voltage in the range from 50 - 230 V.
4. - preheat. Heating up the bulb filaments. Set in the range from 0 - 10 %.
5. - lack of signal. It determines functioning of the dimmer according to parameters defined in
case of DMX signal interruption. There are 9 options to choose from:
- turning all outputs on at 100%,
-
turning all outputs off,
- the last received value is held,
- slow output switching off (about 20 secs),
... - programmable scenes,
- factory-defined chaser,
- programmable chaser.
The dimmer allows to define the following operation parameters:
1. The group parameters - menu
Chosen settings are same for all channels. In case of the DMX address, the displayed value is
related to the first channel. For all the other channels subsequent address values are
assigned.
2. Individual parameters - menu
Each channel can be programmed individually. It applies also to the DMX address. The same
address can be programmed for several channels.
Group parameters have higher priority then individual ones. It means that when the DMX
address is programmed in the mode, the previous settings for all twelve channels will be
cancelled.
3. Scenes and chasers programming - menu
This function enables to program:
-
settings for all three scenes
-
twelve steps settings and the speed and fading of programmable chaser
-
speed and fading of the factory-defined chaser
4. Measurement functions - menu
This function allows to check the internal dimmer temperature and supply voltage values.
Содержание PX091
Страница 1: ...MANUAL AC Dimmer 12 x 1200 W PX091 R...