Operating and maintenance instructions

EN

6.4 Exhaust filters replacement

Very dirty exhaust filters may cause a considerable pump temperature increase and in 
extreme cases oil lubricant spontaneous ignition.
Maximum allowed pressure in the tank is 0,6 bar measured at the maximum capacity 
(when the pump is working with the inlet open to atmospheric pressure). 
If a pressure gauge has been fitted to the tank, check the exhaust filter blockage with 
the pump warm.
To replace the filter, remove the cover (pos. B2) by unscrewing its screws (pos. B1).
Unscrew the screw (pos. B4), remove the washers (pos. B5-B6) and then the fixing 
cartridge disk (pos. B7).
Replace all the exhaust filters (pos. B) and their O Rings (pos. B8). Reassemble the fixing 
cartridge disk, the washers and tighten the screws.
Reassemble the discharge cover. If necessary, replace the gasket (pos. B3).

6.5 Float valve

If the float valve doesn’t operate well, you may notice:
- the oil carry out from the discharge port
- pump performance loss. 

The reasons could be as follows:
- oil recovery line is blocked or the float valve mechanism got blocked due to dirties or 
sludges.
- oil recovery line doesn’t close perfectly due to dirties or because the seal is worn.

In this case, the float valve must be disassembled, cleaned and then its good operation 
must be checked.
Remove the cover Fig. 9 (pos. B2) unscrewing its screws (pos. B1). Remove the float 
valve (pos. Z) from its housing after having unscrewed its grub-screw (pos. Z1). Clean the 
float valve and its internal reduction fitting, with compressed air by blowing the opposite 
direction with respect to the normal oil flow. Fit the float valve in its housing. Check the 
float valve good operation before closing the cover (pos. B2).
- Switch the pump on without having any oil deposit and check if it achieves the limit 
pressure.
- Fill with oil until the valve 
opens. Wait until it closes, 
while checking if the pump 
keeps its ultimate pressure 
constant.
If not, the float valve must 
be replaced completely.

Fig.10

Z

Z1

Содержание EU300F

Страница 1: ...EU300F EU300F HWT Lubricated vane vacuum pump Operating and maintenance instructions Publication Number LI 4431 00 January 2018 EN TRANSLATION...

Страница 2: ...tallation page 11 5 5 Electrical connection page 12 5 6 Commissioning page 13 5 7 Tips for using page 13 5 8 Water vapour intake page 14 6 Servicing page 14 6 1 General information page 14 6 2 Oil cha...

Страница 3: ...takes place The suggestions given to the staff engaged in the installation and servicing assumes that the personnel is expert and prepared in facing any problem of servicing both mechanical and electr...

Страница 4: ...n At the pump inlet there is a mesh filter in order to protect it from solid parts having diameter larger than 1 5 mm Furthermore anintegratednon returnvalvepreventstheoilcomingbackandthereturn of air...

Страница 5: ...the pump to create even limited pressures WARNING It is forbidden to install the pump in a potentially explosive environment 2 4 Protections The pump must be protected against suction of dust solids o...

Страница 6: ...r can cause an oil leakage Avoid the dispersion to the ground and the pollution of other materials In case that any air containing dangerous substances must be pumped down for example biological or mi...

Страница 7: ...withanyother law in force in the Country of use Besides electrical equipment must comply with EN 61000 6 4 and EN 61000 6 2 standards concerning electromagnetic compatibility and electromagnetic immun...

Страница 8: ...the packaging is intact or shows any signs of damagesoccurredduringtransportation Ifthereisnodamage proceedtotheunpacking and check the machine further In case of damages are found inform immediately...

Страница 9: ...ble for the motor weight about 45 Kg 50 Hz and about 50 Kg 60 Hz To assure the continuity of the equipotential circuit of the pump clean the contact surfaces very well by removing any grease or protec...

Страница 10: ...the machine where the pump has been installed To assure a sufficient cooling avoid exceeding 40 C of ambient temperature The pump must be protected against jets or sprays of water that may penetrate...

Страница 11: ...ntifies the inlet port For further information please refer to the RDT attached herewith 5 4 Discharge air pipe line installation If the pump has been installed in a room with poor air exchange it is...

Страница 12: ...the data stamped on the motor name plate The electric motor must be protected against overload The full load amperage value on the motor name plate must be considered when sizing the electrical compo...

Страница 13: ...NOTE a quantity of oil greater than necessary may clog the oil separator and damage the pump or the electric motor 5 7 Tips for using When the room temperature is lower than 10 C it is a good practic...

Страница 14: ...bring the pump temperature to its operating value At the end of the working cycle in case of further presence of condensate in the oil let the pump run for at least thirty minutes at the maximum vacuu...

Страница 15: ...uit SERVICING FREQUENCY DESCRIPTION OF THE OPERATION AUTHORIZED PERSONNEL 24 Hours every day Check oil level before starting Operator 100 Hours every week Clean the external inlet element with a blast...

Страница 16: ...the plugs and discharge the rest of the oil If the oil is polluted or if some water is in the oil clean the pump by letting it run with a suitablequantityofoil uptotheminimumlevelshownonthetank atmaxi...

Страница 17: ...valve doesn t operate well you may notice the oil carry out from the discharge port pump performance loss The reasons could be as follows oil recovery line is blocked or the float valve mechanism got...

Страница 18: ...odel kW V Hz position reference on the spare parts list description and quantity needed Different types of maintenance kits are available ref RDT attachment 7 Lubricants Oil recommended for generic us...

Страница 19: ...lubricant from the pump prior to shipping the pump back 10 Disposal Meaning of the WEEE logo found in labels The following symbol is applied in accordance with the EC WEEE Waste Electrical and Electro...

Страница 20: ...t our workshop Oil leak Shaft oil seal rings worn Replace oil seal rings Oil filling discharge plugs are leaking Check the plug has been closed replace the gasket Inefficient oil recovery system Check...

Страница 21: ...21 LI 4431 00 IT EN Operating and maintenance instructions EN...