10
LI 4431.00 (IT-EN)
Operating and maintenance instructions
EN
5.2 Location
WARNING:
The pump must be installed in a protected area (see safety rules).
It must be fastened with support feet on horizontal surface.
It must be accessible for correct and easy maintenance, by respecting the minimum
distances from possible obstructions (see figure 6).
It must be accessible to suitable lifting equipment.
NOTE:
Ensure the air exchange in the room or inside the machine where the pump has been
installed.
To assure a sufficient cooling, avoid exceeding 40°C of ambient temperature.
The pump must be protected against jets or sprays of water that may penetrate the
tank through the exhaust port.
Whenever the pump is installed outside, it must be protected against atmospheric
agents and it must be used with an oil suitable for low temperature.
Avoid warm air coming from the exhaust or the cooling fans causing discomfort to the
personnel.
Do not install the pump in a dusty area or where other materials may block or cover
the cooling surfaces quickly.
Fig.6
A
C
B
D
300 mm
100 mm
300 mm
350 mm
A
B
C
D