ELECTRIC WATER HEATER TROUBLESHOOTING GUIDE

 

 

TROUBLE PROBABLE 

CAUSE 

REMEDY 

No hot water    

Thermostat(s)   

Check to assure proper thermostat setting. 

Contractors will not pull in 

Check continuity between all three thermostats or pressure 
controls. Complete circuit. If one is open, it must be replaced. 

Control circuit switch is in OFF position 

Close switch. (Turn to ON position) 

Control circuit fuse blown 

Isolate cause for failure and replace fuse. 

Contractor(s) coil open 

Check continuity. Replace coil if not a complete circuit. 

Time delay sequencer not operating 

Check for 120 volts to coil on first sequencer step. Allow ample 
time for additional steps to energize. If steps do not energize in 
reasonable time, replace only the defective relay step. See 
wiring diagram. 

Proportional sequencer not operating 

Check for 120 volts to line connection (L) on sequencer. Check 
fuse for continuity. See wiring diagram. Consult factory. 

Low water cutoff open 

Check for open circuit. Check water level in tank. Replace low 
water cutoff if defective. 

Heating elements 

Check for open legs. (See table 2). 

Insufficient hot 

water  

  

Heater not large enough to satisfy peak 
demands 

Add booster or additional kw input. Consult local PVI 
representative. 

Hot water lines not insulated 

Add insulation; it will protect against heat loss and save on cost 
of operation. 

Power fuse(s) blown 

Check fuses for continuity. Replace if blown. If blown, determine 
cause of break before replacing with same type fuse. 

Contractor(s) not closing 

Check coil for continuity. If defective, replace. 

Thermostat(s)  not correctly set 

Check to assure proper thermostat control setting. 

Element(s) not heating 

Check for proper amperage draw. Check for proper ohm 
resistance. Replace if defective. Consult factory. 
(See table 1) 

Burned or 

discolored wires 

Loose connections 

Tighten all connections. If charred, replace wire with wire of 
same type and size. 

Dirty or pitted contactor points 

Remove contactor points and inspect. If dirty, clean with emery 
paper. CAUTION: Point must remain flat. If pitted or burned, 
contractor points must be replaced. 

Blown fuses 

Loose connection. Defective element 

Check all connections for tightness. Check ohm resistance in 
electric elements. Replace. 

High or low 

voltage 

Local utility 

Check with local utility. 

High or low 

amperage 

High or low voltage. Defective element 

Check with local utility. Low amperage, check fuses, tighten 
connections. Check ohm resistance on elements. 

Wire burned  

or melted at 

element 

Loose connections. Water leaking on elements 

Tighten connection and replace wire. Isolate leaking water and 
repair. Replace wire with same type and size. 

 

Содержание 500-6

Страница 1: ...t perform installation and service WARNING Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any other items affecting safe appliance operation Failure to follow these instructions can cause property damage personal injury or loss of life TO THE INSTALLER After installatio...

Страница 2: ...DURAWATT ELECTRIC WATER HEATER PV500 6 09 07 2 TYPICAL CONSTRUCTION FIGURE 1 Without 23 Diameter Tank Access FIGURE 2 With 23 Diameter Tank Access ...

Страница 3: ...THE PHYSICALLY HANDICAPPED HOSPITALS AND NURSING HOMES ELDER CARE FACILITIES AND REST HOMES ORPHANAGES AND CHILD CARE FACILITIES OTHER INSTALLATIONS WHERE RESPONSE TO CONTACT WITH HOT WATER MAY BE SLOWER OR WHERE THE DANGER OF HOT WATER CONTACT IS GREATER Thermostatically controlled mixing valves must be used in the design of the potable hot water system Potable hot water should be tempered to no ...

Страница 4: ... 3 Locate the foundation on a pitched floor near a suitable drain or make other provisions to prevent contact to areas of the building subject to water damage should the boiler or a water connection leak The drain must be sufficient to contain water in excess of 210 F INSTALLATION WARNING Use industry standard safe rigging methods when attempting to lift or move this product Failure to follow thes...

Страница 5: ...MPORTANT Check all wiring connections in heater and element enclosure to assure tightness prior to energizing NOTE Use only copper wire of proper sizing for incoming service Damage resulting from use of aluminum wiring is excluded from coverage under the warranty of this unit ELECTRONIC LOW WATER CUTOFF The device consists of a probe in the tank that acts as a switch closed when submerged in water...

Страница 6: ...e elements have 3 terminals 1 phase elements have 6 terminals FIGURE 3 2 Check all electrical connections for tightness before turning the unit on 3 Energize manual disconnect switch Check for proper voltage with voltmeter on power circuit Voltage should not vary more than 5 from voltage shown on data plate If voltage exceeds these limits immediately turn off main disconnect and contact utility co...

Страница 7: ...proper performance MAINTENANCE A preventative maintenance program is required to ensure a long trouble free life of the water heater Maintenance Schedule COMPONENT OPERATION INTERVAL REQUIRED Tank Sediment Removal Every 3 Months Flushing Relief Valve Inspect Every 6 Months Test Electrical Connections Inspect Monthly Inspect for wire discoloration Electric Elements Check Every 6 Months Amp Draw Ele...

Страница 8: ...ief valve mounting location Low Water Cut Off The standard low water control is electronic Inspection should be made of the electrode on water heaters equipped with electronic low water devices Electrical Connections Check all electrical connections approximately one to two weeks after initial start up to assure tightness Heating and cooling from operation can loosen connections Visually inspect w...

Страница 9: ...of the scale buildup is also determined by the watt density of the element It is good maintenance practice to remove and clean 80 W in 18kW density elements on a monthly basis The interval between removal and cleaning can usually be extended to six months when 40 W in 9kW density elements are installed Most installations where 20 W in 4 1 2kW density elements are used require only annual cleaning ...

Страница 10: ... READING MAY VARY FROM ZERO DIRECT SHORT TO SEVERAL HUNDRED OHMS PARTIAL SHORT IN ANY CASE WHERE THE OHM READING IS NOT INFINITY THE ELEMENT SHOULD BE REPLACED B C 26 39 39 C A 26 39 18 240 A B 7 20 B C 7 10 10 C A 7 10 18 208 A B 5 15 B C 5 7 5 7 5 C A 5 7 5 9 480 A B 51 153 B C 51 76 5 76 5 C A 51 76 5 9 240 A B 13 39 B C 13 19 5 19 5 C A 13 19 5 9 208 A B 10 30 B C 10 15 15 C A 10 15 4 5 480 A ...

Страница 11: ...DURAWATT ELECTRIC WATER HEATER PV500 6 09 07 11 FIGURE 7 FIGURE 6 TYPICAL WIRE TERMINATIONS FIGURE 8 TYPICAL SINGLE PHASE WIRING TYPICAL THREE PHASE WIRING FIGURE 10 FIGURE 9 ...

Страница 12: ...efore the 40W in 2 is rated for 14 kW instead of 9 kW KW VOLTAGE 3 Ø AMPS PER ELEMENT 1 Ø AMPS PER ELEMENT AMPS PER LEG AMPS TOTAL AMPS PER LEG AMPS TOTAL 14 kW 600V 13 1 2 13 1 2 7 kW 600V 7 7 18 kW 480V 22 22 9 kW 480V 11 11 4 5 kW 480V 5 1 2 5 1 2 18 kW 240V 44 44 25 75 9 kW 240V 22 22 13 38 4 5 kW 240V 11 11 6 18 18 kW 208V 50 50 29 87 9 kW 208V 25 25 15 44 4 5 kW 208V 12 1 2 12 1 2 7 22 TABLE...

Страница 13: ...ecial fasteners with similar grade 8 bolts washers and nuts Install the flange bolts and nuts with a flat washer under each bolt head and nut First snug them in an alternating star pattern Then using a calibrated torque wrench and in an alternating star pattern tighten the bolts in 2 increments 95 ft lbs and 145 ft lbs Use a small amount of silicone RTV to hold the o ring in place while positionin...

Страница 14: ...put Consult local PVI representative Hot water lines not insulated Add insulation it will protect against heat loss and save on cost of operation Power fuse s blown Check fuses for continuity Replace if blown If blown determine cause of break before replacing with same type fuse Contractor s not closing Check coil for continuity If defective replace Thermostat s not correctly set Check to assure p...