background image

Fluid Section 

 

1)

 

Drop the packing’s (5) into the fluid sections (4), and screw in the packing nuts 
(6) but leave finger tight until assembled with the air sections. 

2)

 

Thread the standoffs (25) into the fluid sections (4) and tighten using pliers with 
soft grip ends.  

3)

 

Mount the 006 Kalrez o-rings (15) onto the seats (2) and push the seats into the 
bottom of the fluid sections (4).  When inserting the seats, work the o-ring into the 
fluid body with finger to prevent shearing of the edge of the o-ring. 

4)

 

Place the 010 Kalrez o-rings (21) into the grooves on the top of the manifold. 

5)

 

Place the fluid sections (4) onto the manifold and assemble with the eight 
machine screws (24) tightening with a 3/32” Allen Key.  
*Note: Be sure the 1/8” fluid inlets will align on the face of the valve.  

 

Assemble Sections 

 

1)

 

Back out the stroke adjust bolts (19) by turning them counter clockwise until the 
end of their travel.  

2)

 

Apply a small amount of silicone grease to the end of the needles (3) and insert 
them into the packing nuts (6) and slide the two sections together. 

3)

 

Align the air holes of the air sections on the same face as the 1/8”npt fluid inlets 
of the fluid section then connect the sections using the four machine screws (13) 
tightening them down evenly with a 3/32” Allen key. 

4)

 

Using the tip of a 3/32” Allen key, tighten the packing nuts (6). 

 

 

Spare Parts 

 

PVA offers standard spare parts kits for all dispensing valves. These kits are 

stocked for immediate shipment and allow replacement of all wearable parts of the valve.   

 
The spare parts kit for this valve, product number 

PC1-SP

, includes the following 

components: 

 

PC1-SP

 Includes: 

 

Qty 

Part Number 

Description 

V302 

Seat 

114-5247 

Needle 

V305 

Packing, Teflon 

VLV-014B 

O-ring, Buna 

VLV-008B 

O-ring, Buna 

VLV-006K 

O-ring, Kalrez 

VLV-004B 

O-ring, Buna 

VLV-010K 

O-ring, Kalrez 

Содержание PC100

Страница 1: ...PC100 TWO COMPONENT DISPENSE VALVE Version B12 1403 Operation Manual 1 MUSTANG DRIVE COHOES NY 12047 PHONE 518 371 2684 FAX 518 371 2688 info pva net www pva net ...

Страница 2: ... Part A and part B fluids will flow into the valve separately and out of the valve separately into a disposable static mixer No disassembly and cleaning of the valve is required at the end of the day The PC100 has a divorced design comprising of two major sections These include 1 Two air sections red anodized portions 2 Fluid section stainless steel portion The separate air sections are aluminum b...

Страница 3: ... the midsection of the valve are air to close the valve The ports located closest to the mid section of the valve are air to open the valve Air supplies used to open and close the valve should be tied to the same solenoid to maintain uniform control Quick connect air fittings are typically supplied with the PC100 to fit 5 32 tubing Note that the valve should be normally in the closed position Flui...

Страница 4: ...can be seen going up and down in the center simultaneously Note If the valve is not cycling properly refer to the Troubleshooting section 4 When the fluid delivery system is connected to the valve pressurize the fluids to be dispensed 5 Once again cycle the valve open to purge Part A and B should begin to flow separately out of the fluid manifold 1 continue dispensing until air is removed 6 Check ...

Страница 5: ...ing removal that there are springs 17 forcing the air sections away from the fluid section 6 Pull the air sections red anodized portions away from the fluid section stainless steel portion 7 Clean off the tip of the stainless steel needles 3 8 From the fluid section of the valve unthread and remove the packing nuts 6 and the packing s 5 9 Using a 3 32 Allen Key remove the eight machine screws 24 t...

Страница 6: ...on the inside groove of the stroke adjust bolts 19 3 Thread the stroke adjustment assemblies into the upper air bodies 11 4 Mount the first two 014 Buna o rings 9 on the ends of the upper air bodies 11 and the final two 008 Buna o rings 12 on the end groove of the stroke adjust bolts 19 Back out the stroke adjusts by turning them counter clockwise to the end of their travel 5 Drop the needles 3 in...

Страница 7: ...oke adjust bolts 19 by turning them counter clockwise until the end of their travel 2 Apply a small amount of silicone grease to the end of the needles 3 and insert them into the packing nuts 6 and slide the two sections together 3 Align the air holes of the air sections on the same face as the 1 8 npt fluid inlets of the fluid section then connect the sections using the four machine screws 13 tig...

Страница 8: ......

Страница 9: ......

Страница 10: ... 8 V201 Lower Air Body 2 9 VLV 014B O Ring Buna 4 10 V202 Piston 2 11 V228 Upper Air Body 2 12 VLV 008B O Ring Buna 4 13 SH5 40x2 0 Cap Screw 4 14 SH5 40x2 25 Cap Screw 4 15 VLV 006K O Ring Kalrez 2 16 VLV 004B O Ring Buna 2 17 V050 Spring 2 18 V001 Set Screw 2 19 V230 Stroke Adjust 2 20 V229 Lock Nut 2 21 VLV 010K O Ring Kalrez 2 22 V007 Plug 2 23 165 38NWF Retaining Nut for static mixer 1 24 SH5...

Страница 11: ...sen packing nut Replace parts as necessary Flip valve upside down and cycle until air bubbles are removed Valve leaks from mid section Packing nut is loose Packing is worn Tighten packing nut until snug Replace packing Valve does not dispense anything Fluid pressure is too low Material cured in fluid section Stroke adjustment bolt is set too low Increase fluid pressure Disassemble and clean valve ...

Страница 12: ...es extend only to the original purchaser Third party warranty claims will not be honored at any time Prior to returning a product for a warranty claim a return authorization must be obtained from PVA s customer service department Authorization will be issued either via the telephone facsimile or in writing upon your request To qualify as a valid warranty claim the defective product must be returne...

Отзывы: