Safety
Due to material contents being under pressure eye protection is required for
operators. Refer to MSDS sheets on material being dispensed for other precautions.
Setup
The PC100 requires a 2-position, 4-way air solenoid valve to actuate the air
section. The valve should be operated with clean, dry air between 60-100psi. Four #10-32
threaded air ports are located on the air sections of the valve. The ports located furthest
from the midsection of the valve are air to close the valve. The ports located closest to the
mid-section of the valve are air to open the valve. Air supplies used to open and close the
valve should be tied to the same solenoid to maintain uniform control. Quick connect air
fittings are typically supplied with the PC100 to fit 5/32” tubing. Note that the valve
should be normally in the closed position.
Fluid is supplied to the PC100 through the 1/8”npt ports located on the stainless
steel fluid section of the valve. Part A fluid should be connected to the port on the left
and Part B fluid should be connected to the port on the right.