![PVA DeltaTherm IR Cure Module Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/pva/deltatherm-ir-cure-module/deltatherm-ir-cure-module_operation-manual_1628583029.webp)
DeltaTherm IR Cure Module
Revision C
/
September 2022
Page 29 of 41
Global Settings
225B224B224B
21B21B21B
Figure 22: Global Settings
1.
120B119B119B
Press
Unit Selection
to toggle between Metric and Standard.
2.
121B120B120B
Press
Process Timeout
to enable or disable board process timeout in Auto Cycle.
3.
122B121B121B
Press
Clear Board
to enable or disable the clear board check when entering Auto
Cycle. If disabled, upon entering Auto Cycle, boards in the oven will not move
downstream until the oven is at temperature and ready to process boards.
4.
123B122B122B
Press
Auto Idle Timeout
to enable or disable the idle timeout in Auto Cycle. When
enabled, if no boards are being processed in the specified timeout, a silent timeout
fault will occur and the oven will exit Auto Cycle, turning the heater panels off.
5.
124B123B123B
Press
Conveyor Width
to enable/disable the conveyor width move to current recipe
position after homing and when entering Auto Cycle.