![PVA DeltaTherm IR Cure Module Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/pva/deltatherm-ir-cure-module/deltatherm-ir-cure-module_operation-manual_1628583020.webp)
DeltaTherm IR Cure Module
Revision C
/
September 2022
Page 20 of 41
Manual Mode
IR Panels
209B208B208B
The panel temperature is shown for each zone. A zone is an area in the oven that is
controlled and monitored independent of other areas. Usually an oven has four zones.
210B209B209B
11B11B11B
Figure 12: Manual IR Panels
1.
67B66B66B
Select the
Heater Panel
switch to turn the desired panel on or off. The indicator to
the left of the switch will show the heat output. The heater panel will heat up to the
current setpoint.
2.
68B67B67B
The
Setpoint
boxes are the target set points for each zone and heater panel. To
change the target
Setpoint
, press the designated box. A new screen will be shown.
•
69B68B68B
The left side box in the Zone Control area is the target temperature (display
temperature is filtered) for each zone and the deviation point for that zone.
•
70B69B69B
Touch the screen and a keypad will be shown.
•
71B70B70B
Enter the necessary value.
•
72B71B71B
Push
ENT
, and the zone screen will be shown again.
3.
73B72B72B
The
Actual
boxes show the actual temperatures (display temperature is filtered) for
each zone.
4.
74B73B73B
Select
Apply to All
to copy the setpoints of the Zone 1 upper and lower heater panel
to every zone and panel.
5.
75B74B74B
Select the
View Trend