![PVA DeltaTherm IR Cure Module Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/pva/deltatherm-ir-cure-module/deltatherm-ir-cure-module_operation-manual_1628583018.webp)
DeltaTherm IR Cure Module
Revision C
/
September 2022
Page 18 of 41
Auto Cycle
207B206B206B
Auto Cycle is the normal operating mode for the DeltaTherm IR Cure Module. In Auto Cycle,
the cure module can operate as part of a production line. All communication with adjacent
machines is done without operator input. In Auto Cycle, the machine uses the parameters in
setup mode. The screen below shows Auto Cycle with four zones top and bottom.
208B207B207B
10B10B10B
Figure 11: Auto Cycle
1.
50B49B49B
The
Panel Temperature
shows the current temperature of the heater panel.
2.
51B50B50B
The
Panel Temperature Setpoint
shows the current recipe’s temperature setpoint
of the heater panel.
3.
52B51B51B
The
At
Temperature
indicator will light up when the panel temperature is within
the allowable setpoint deviation value.
4.
53B52B52B
The
Current
Recipe
Name
will display at the top of the screen.
5.
54B53B53B
The
Board
Counter
displays the number of boards in the oven. In the event of an
incorrect value (PIP flashing), press and hold for 5 seconds to reset this to zero
6.
55B54B54B
The
Autocycle Messages
section displays the current Auto Cycle state and status
messages.
7.
56B55B55B
Press to the
Heater Panel Trend
icon to view a graph of panel temperature values
over time.
8.
57B56B56B
To view the next set of panels and zones, press the
Next Zone
button.
9.
58B57B57B
The
SMEMA Status
shows the current status of SMEMA inputs and outputs.
10.
59B58B58B
The current
Conveyor Speed
will display at the bottom of the screen.