9
Undersink | Drinking Water Filter Systems
Quick Connect Fittings
FIGURE 3
1
. Cut the tube square and push in to
the tube stop. For metal tube remove
burrs and chamfer tube end to prevent
O-Ring seal being damaged.
DISCONNECTION PROCEDURE
4
. Push collet against body and
slide tube out of fitting.
2
. Fitting grips before it seals. Ensure
tube is pushed in to tube stop.
HOW TO USE QUICK CONNECT FITTINGS
3
. Tube is secured in position.
USER GUIDELINES
• Minimum operating pressure 100 kPa.
• Maximum operating pressure 875 kPa.
• Do not allow exposure to temperatures below 4°C.
• Maximum operating temperature 38°C.
• Nominal flow rate 4 Lpm.
• This system must be installed according to local plumbing codes on the cold water line.
• Replacement Cartridges: See Cartridge replacement section
• This system requires regular replacement of the filter cartridge to maintain proper operation.
Varying chlorine, sediment, or organic substance levels may affect replacement frequency.
• Be sure to change the filter cartridge at least every 8,000 litres or 6 months which ever occurs first;
or whenever you detect a change in taste, odour, or decrease in flow. 8,000 litres is approximately
equal to using 20 litres daily for one year.
• When replacing cartridge, ensure you reset the LED reminder light by removing/replacing the
battery from the rubber seat. Please refer to page 8 for a detailed diagram.
Caution: Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.