Installation Procedure

Cartridge Installation/Changeout

To change the filter cartridges adhere to the following procedure.

1.  Close ballvalve to prevent water flow.

2.  Relieve water pressure by operating faucet lever.

3.  Unscrew filter housing bowl using the spanner wrench and discard cartridges. When 

removing housings place a container underneath to catch any spillage.

4.  Cleanse the inside of the housing using warm water. Check O-Ring and lubricate 

with food grade silicone lubricant or similar. Replace O-Ring if kinked or damaged. 

(Part No: FPOR)

5.   Install new cartridges and replace housing screwing them up HAND TIGHT ONLY. 

Sediment filter is on the inlet side and chemical on the outlet side.

6.  Reset LED indicator  by following instructions on page 8.

7.  Restore water supply & check for leaks, rectifying them, if any, before leaving the 

unit.

After installing cartridges flush unit for 5 - 10 minutes.

Содержание SH SERIES

Страница 1: ...de Undersink Drinking Water Systems TS SERIES SH SERIES For correct operation installation it is essential to observe these instructions AS NZS 3497 Licence No WM 74617 Australian Certification Services APR2018 ...

Страница 2: ...td 2018 What s inside Introduction 3 Operation 3 Cartridge Installation 4 Installation Guide 5 Installation Procedure 6 Parts Description 7 Battery Installation 8 Quick Connect Fittings 9 Performance Data 10 Warranty 11 Contact Information 12 What s Inside ...

Страница 3: ...your local Puretec stockist or call our Puretec Customer Service Helpline The Puretec filter systems cartridges need replacing regularly to maintain optimum performance This is a simple procedure when following instructions For cartridge replacements contact your nearest Puretec stockist Customer Service Helpline 1300 140 140 Australia 0800 130 140 New Zealand Operation The Puretec undersink syste...

Страница 4: ...eplacing cartridge ensure you reset the LED reminder light by removing replacing the battery from the rubber seat Please refer to page 8 for a detailed diagram Installation This system comes complete with an installation kit enabling it to be connected to 15mm copper pipe Cold supply only hot water should be filtered prior to heating Included is a control valve incorporating backflow prevention an...

Страница 5: ...the faucet into the hole in sink or bench Slip the large plastic washer and lock washer onto threaded end of faucet and screw on nut and tighten making sure faucet is correctly positioned on top 6 Reset LED indicator by following instructions on page 8 7 Install housing assembly by positioning it in the desired location marking the position of fixing holes and fixing with mounting screws Allow roo...

Страница 6: ...gs place a container underneath to catch any spillage 4 Cleanse the inside of the housing using warm water Check O Ring and lubricate with food grade silicone lubricant or similar Replace O Ring if kinked or damaged Part No FPOR 5 Install new cartridges and replace housing screwing them up HAND TIGHT ONLY Sediment filter is on the inlet side and chemical on the outlet side 6 Reset LED indicator by...

Страница 7: ... T 2 Flexible Tubing 3 Pressure limiting Multivalve 4 Housing Assembly Twin Pictured 5 Mounting Bracket 6 Tube Nut and Ferrule 7 Tube insert 8 Faucet Lock Nut and Washer 9 Black plastic washer 10 Black Rubber Washer 11 Escutcheon Plate 12 Long Reach Faucet 12 6 7 8 10 9 11 3 4 1 FIGURE 1 5 2 2 2 ...

Страница 8: ...black battery seat from the faucet lever handle see figure 2 2 Install battery into the battery seat positive side up Note red light flashes twice and then followed by the blue light 3 Reinstall battery seat assembly into the faucet lever Important note Battery must be replaced when changing cartridges 5 Red light flashes indicates your cartridges are due to be changed usage has exceeded 3 000 min...

Страница 9: ...d according to local plumbing codes on the cold water line Replacement Cartridges See Cartridge replacement section This system requires regular replacement of the filter cartridge to maintain proper operation Varying chlorine sediment or organic substance levels may affect replacement frequency Be sure to change the filter cartridge at least every 8 000 litres or 6 months which ever occurs first ...

Страница 10: ...1996 ND Not Detected This appliance meets the domestic water treatment appliance Standards AS NZS3497 for the following water treatment processes Class Treatment type Function Pass I Microbiological Status Will stop bacteria increasing but will not remove them unless II a is passed N A Bacteriostatic II Microbiological Treatment II a Bacteria Removal Will remove or inactivate bacteria N A II b Vir...

Страница 11: ...t Puretec s discretion including chargeable inspection and labour costs incurred Warranty Australia This warranty is given by Puretec Pty Ltd ABN 44 164 806 688 37 43 Brodie Road Lonsdale SA 5160 telephone no 1300 140 140 and email at sales puretec com au This warranty is provided in addition to other rights and remedies you have under law Our goods come with guarantees which cannot be excluded un...

Страница 12: ......

Отзывы: