Performance Data
Substance
Guidelines*
Average
Influent
Concentration
Max Effluent
Concentration
Min Percent
Removal
Average
Effluent
Concentration
Average
Percent
Removal
NSF Standard 42 Drinking Water Treatment Units
Chlorine
(11,355 L)
5 - Health
0.6 - Aesthetic
2.1
0.3
50%
0.25
>94%
Standard 53 Cyst Live Cryptosporidium POU/POE (TS200)
Cyst
<1
100,000
ND (1)
99.98% +
ND (1)
99.99%
Test Parameters
Hardness, Total mg/L
120
TDS mg/L
290
Temp deg C
21°C
Turbidity NTU
0.1
pH
7.57
*Australian Drinking Water Guidelines - 1996
ND = Not Detected
This appliance meets the domestic water treatment appliance Standards AS/NZS3497 for the following
water treatment processes:
Class
Treatment type
Function
Pass
I
Microbiological Status
Will stop bacteria increasing, but will not
remove them unless II(a) is passed
N/A
Bacteriostatic
II
Microbiological Treatment
II (a)
Bacteria Removal
Will remove or inactivate bacteria
N/A
II (b)
Virus Removal
Will remove or inactivate virus
N/A
II (c)
Protozoa Removal
Will remove or inactivate Cryptosporidium
and Giardia, but will not remove or
inactivate bacteria and virises unless II(a)
and II(b) is passed
YES
(TS200)
III
Turbidity & Particulate Reduction
Reduces cloudiness
YES
IV
Taste & Odour Reduction
Reduces taste & odours
YES
V
Chemical Treatment
Decreases chlorine
YES