Puretec water care products are designed, manufactured and supported by Puretec Pty Ltd the name 
you can trust for viable and proven water solutions. The complete range of Puretec products are 

developed, refined, made to meet and exceed stringent specifications for the worldwide market.

Important: Sales of products are subject to our Terms and Conditions which are available upon request. 

All specifications, information and photos are a guide only and are subject to change without notice. 
Please ring to confirm details. Warning: For correct operation of this appliance it is essential to observe 

manufacturer’s instructions.

Warranty

Any claim under this warranty must be made within 10 years of the date of purchase of the product. 
This product is warranted to be free of defect of material and workmanship for 10 years from date of 
purchase. 10 year warranty is 1 year parts and labour plus 9 years parts only. Excludes cartridges.

Puretec is renowned for its quality and after-sales support so if you have any issues please call 1300 

140 140 (AU) or 0800 130 140 (NZ). To make a warranty claim, contact us directly or the place of 
original purchase. All costs relating to a warranty claim must be approved by Puretec prior to any work 
being carried out.

Puretec will pay your reasonable, direct expenses of claiming under this warranty. You may submit 
details and proof of your expense claim to place of purchase for consideration.

The warranty only applies if the product was used and/or installed in accordance with the user guide 
and/or installation instructions. This warranty is given in lieu of all other express or implied warranties 

and manufacturer shall in no circumstance be held liable for damages consequential or otherwise or 
delays caused or faulty manufacturing except as excluded by law.

Applicable to all above, is that the warranties need to be approved by Puretec to ensure product 
was not incorrectly used, installed or claimed. False and incorrect claims will be pursued at Puretec’s 
discretion, including chargeable inspection and labour costs incurred.

All installation and service work should be completed by qualified tradespeople. Faulty operation 

due to unqualified persons will result in voided warranty coverage. 

Warranty

Содержание PureMix Z2

Страница 1: ...7 Licence No WM 74617 Australian Certification Services User Guide Compact High Flow Inline Water Filter System PureMix Z2 For correct operation installation it is essential to observe these instructions NOV2021 ...

Страница 2: ... quality materials and components and will give years of spring fresh water if maintained properly The Puretec PureMix Inline Water Filter System cartridge needs replacing regularly to maintain optimum performance This is a simple procedure when following instructions For cartridge replacements contact your nearest Puretec stockist Customer Service Helpline 1300 140 140 Australia 0800 130 140 New ...

Страница 3: ...roperty damage this product should be regularly examined for leakage and or deterioration and replaced when necessary We strongly recommend that a drain pan plumbed to an appropriate drain or outfitted with a leak detector be used in those applications where any leakage could cause property damage We also strongly recommend that the water supply be turned off upstream to the water filter system ta...

Страница 4: ...sembly Z6 R Z7 R Cartridge HOT COLD Braided Hose Stem Adaptor Minimum 70 mm clearance for cartridge changes Note Allow extra free space around the system to avoid accidental impact Pressure Limiting Valve Multivalve 3 8 High Pressure Tubing Also includes Extending Kit Stem Adaptor Vertical Installation Diagram ...

Страница 5: ...ead Assembly Z6 R Z7 R Cartridge HOT COLD Braided Hose Stem Adaptor Minimum 70 mm clearance for cartridge changes Note Allow extra free space around the system to avoid accidental impact Pressure Limiting Valve Multivalve 3 8 High Pressure Tubing Also includes Extending Kit Stem Adaptor Horizontal Installation Diagram ...

Страница 6: ...es can be mounted horizontally and vertically Allow room for the connecting tubes and for removing the cartridge 70 mm Note Knocking the cartridge can cause the cartridge to come out of the locking position To limit the likelihood of this occurring it is best not to store items too close to the system to avoid accidental dislodgement of the cartridge 6 Connect the braided hose cold water line to t...

Страница 7: ...d to comply with Australian New Zealand Plumbing Standards Do not allow exposure to temperatures below 0 C protect from freezing Maximum operating temperature 38 C Nominal flow rate 5 Lpm at 420 kPa This system must be installed according to local plumbing codes on the cold water line only This system requires regular replacement of the filter cartridge to maintain proper operation Varying chlorin...

Страница 8: ...t being seated in the correct position can cause the locking tabs to shear and damage the head and or water leakage When the cartridge is seated in the correct position the arrows on the cartridge and the head will align Cartridge NOT in the correct position Cartridge is in the lock position and will not rotate any further Arrows on the side of the cartridge are aligned Fitting The Cartridge Corre...

Страница 9: ...e for Z2 model Puretec Z2 R 3 Rotate the old cartridge counterclockwise 1 4 turn pull it out and dispose of it 4 Insert the new cartridge into the filter head and rotate clockwise 1 4 turn until the arrows on the head and cartridge align 5 Turn on the water and check for leaks If leaks occur repeat step 2 3 If leaks persist discontinue use and call your supporting dealer 6 Flush filter for 5 minut...

Страница 10: ...upport so if you have any issues please call 1300 140 140 AU or 0800 130 140 NZ To make a warranty claim contact us directly or the place of original purchase All costs relating to a warranty claim must be approved by Puretec prior to any work being carried out Puretec will pay your reasonable direct expenses of claiming under this warranty You may submit details and proof of your expense claim to...

Страница 11: ...the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Warranty New Zealand This warranty is given by Puretec Ltd Reg No 4464398 PO Box 875 Cambridge 3450 NZ telephone no 0800 130 140 and email at sales puretec co nz This warranty is provided in addition to other rights and remedies you have under law Our goods come with guar...

Страница 12: ......

Отзывы: