Compact High Flow Inline Water Filter Systems
DISCONNECTION PROCEDURE
4. Push collet against body and slide tube out of fitting.
1. Cut the tube square and push in to
the tube stop. For metal tube remove
burrs and chamfer tube end to prevent
O-Ring seal being damaged.
2. Fitting grips before it seals. Ensure
tube is pushed in to tube stop.
3. Tube is secured in position.
Figure 3 - How To Use Quick Connect Fittings
Use Guidelines
• Use for mains water supply.
• Minimum operating pressure 200 kPa.
• Maximum operating pressure 520 kPa.
Note:
Where line pressure exceeds 500 kPa, an approved pressure limiting device must
be installed to comply with Australian & New Zealand Plumbing Standards.
• Do not allow exposure to temperatures below 0 °C, protect from freezing.
• Maximum operating temperature 38 °C.
• Nominal flow rate 5 Lpm at 420 kPa.
• This system must be installed according to local plumbing codes on the cold water line
only.
• This system requires regular replacement of the filter cartridge to maintain proper
operation. Varying chlorine, sediment, or organic substance levels may affect
replacement frequency.
• Be sure to change the filter cartridge at least every 38,000 litres or every 6 - 12
months which ever occurs first; or whenever you detect a change in taste, odour, or
decrease in flow.
Caution:
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system.
Quick Connect Fittings