24
Installation & Operation Manual
Copyright © Puretec Pty Ltd 2022
Personal Protective Equipment
Eye / Face
Wear dust-proof goggles.
Hands
Wear PVC or rubber gloves.
Body
When using large quantities or where heavy contamination is likely, wear coveralls.
Respiratory
Where an inhalation risk exists, wear a Class P1 (Particulate) respirator.
Tank Clean-Out (Yearly) - If Required
To help prevent service problems the tank should be emptied and flushed out with a garden
hose when dirt and other insolubles accumulate on a regular basis. Shut off water inlet
supply and depressurise the system before service.
Steps to follow:
1. Disconnect inlet/outlet connections and remove the fill-port head
2. Turn tank upside down and discard old media.
3. Rinse out with a garden hose.
4. Reconnect the fill-port head and inlet/outlet connections.
IMPORTANT SERVICING NOTE:
Under normal circumstances removal of the fill-port head assembly should not be required.
However, if it must be removed, disconnect the plumbing attached to the bypass valve first.
Then, rotate the fill-port head assembly to the left or counter clockwise. Before attempting
any disassembly, pressure should be relieved by shutting off water to the system and
opening a faucet. Upon reassembly, all o-rings should be lubricated with silicone grease.
Reattach fill-port head assembly by rotating to the right or clockwise until fill-port head
assembly is seated to the tank hand tight. Reconnect the plumbing to the bypass valve.
Personal Protective Equipment
Blending Valve Operation (NTX systems)
For blending vale operation information see the Puretec WTV5050 User Guide included with
the NTX models. The Puretec WTV5050 Blending Valve can also be purchased seprately.
Содержание NTS Series