PLCM-E4. 

Ethernet/USB controller of CNC machine

www.purelogic.ru

8 (800) 555 63 74

05. Software installation 

You can assign any address to your PC (e.g. 192.168.10.XX, 

192.168.10.1.) The last value can be different different from 10, 11 

and 12 (192.168.10.10 and 192.168.10.12 addresses for PLCM devices 

established by the manufacturer.

Automatic address assignment installation will work with the controller 

only when there is local DHCP server in the net. In all other cases the 

controller will not contact the plug-in.

After necessary connection option and pressing the button install the 

application apply required connection parameters.

After the installation the application will come with a message:

Choose the connection which you intend to use with PLCM. (In this 

case it is meant that if the computer has several network cards, you 

can install one of them for work with PLCM and the other one use at 

your discretion. We do not recommend to apply this approach in work 

mode, as system loading of third party applies can cause delay of 

tasks execution in Mach3 which can lead to loosing connection with 

the controller. You can use several network cards when testing and 

setting the system). With help of Double click of left mouse button open 

‘network properties’ window. 

Choose Internet protocols TCP/IP and press Properties.

In the opened window displace the switch to ‘Use this IP-address’ 

mode.

Enter any address like 192.168.10.XX in IP-address line, e.g. 

192.168.10.1. The last number can be any but differ from 10, 11 and 

12 (192.168.10.10 and 192.168.10.12 addresses for PLCM devices 

established by the manufacturer). Net mask is 255.255.255.0. After 

pressing OK you will need some time to apply the parameters. Switch 

off firewall and anti virus software (or add MACH3 to exceptions).

(After pressing the button ‘install’ the application will require 2-3 

minutes for introduction of changes. On ‘slow’ PC this procedure 

will take a little more time). If for some reason you failed to make 

connection to PLCM controller in automatic mode, produce setting 

manually. Click on the [Start] icon-[Control Panel], [Network 

connection].

Fig. 11.

 Application window view Set_IP

Fig. 13.

 Network connection option

Fig. 12.

 Message about successful application of settings

Содержание PLCM-E4

Страница 1: ...information 02 Delivery set 03 Technical features 04 Main connectors and indicators 05 Software installation 06 Terms of Warranty INSTRUCTION MANUAL 2 2 3 3 5 16 PLCM E4 Ethernet USB controller of CN...

Страница 2: ...packing Number of inputs 12V direct current 6 0 40 169 x 126 x 20 mm 300m 100 kHz 12 buffered LPT port 500 mOhm 0 24 kg 16 optoisolated 5 buffered LPT port Ethernet USB connector type USB B signal tr...

Страница 3: ...nstallation to some part of a housing The controller has also converter PWN voltage XP34 for control of frequency converter fig 2 The controller has 3 ports The first port is presented by XS3 connecto...

Страница 4: ...t 5 5 output 6 6 output 7 7 output 8 8 output 9 9 output 10 10 input 11 11 input 12 12 input 13 13 input 14 14 output 15 15 input 16 16 output 17 17 output 18 GND 19 GND 20 GND 21 GND 22 GND 23 GND 24...

Страница 5: ...ion When choosing PLCM E4 after Next pressing software installation wizard will offer to execute automatic setting of network adapter PC for correct connection to PLCM E4 fig 8 Fig 3 4 Cable type setu...

Страница 6: ...nd update internal controller software 4 After successful plug in start PLCM control option will appear in menu MACH3 PlugIn Choose this option If you see the window as it is in fig 8 and you cannot c...

Страница 7: ...dynamically assign IP addresses e g it can be a usual home network gateway for internet connection in you local network Receiving address from DHCP server we recommend to make this item active if the...

Страница 8: ...rty applies can cause delay of tasks execution in Mach3 which can lead to loosing connection with the controller You can use several network cards when testing and setting the system With help of Doub...

Страница 9: ...ct defect 3 2 If the defect is proved warranty repair is carried out 4 We do not assume any responsibility for glass electric lamps starters and expendable materials as well as 4 1 Damaged product cau...

Страница 10: ...echnical documentation and is qualified for exploitation Lot number Technical Control Department 4 7 The product which was resold by the initial buyer to the third party 4 8 The product with defects w...

Страница 11: ...onsistent technical improvement You can always download our latest versions at www purelogic ru www purelogic ru Contacts Moscow 7 495 505 63 74 Voronezh 7 473 204 51 56 149 Office 160 Leninsky avenue...

Отзывы: