Purelogic PLCM-E4 Скачать руководство пользователя страница 5

Edition from 05.06.2015 

9

PLCM-E4. 

Ethernet/USB controller of CNC machine

www.purelogic.ru

8 (800) 555 63 74

05. Software installation 

When choosing PLCM-E4 after ‘Next’ pressing, software installation 

wizard will offer to execute automatic setting of network adapter PC for 

correct connection to PLCM-E4 (fig. 8).

Fig. 3/4.

 Cable type setup / speed and duplex mode setup

Fig. 6.

 Driver installation

Fig. 7.

 Automatic network installation

Fig. 5.

 Software installation wizard

Содержание PLCM-E4

Страница 1: ...information 02 Delivery set 03 Technical features 04 Main connectors and indicators 05 Software installation 06 Terms of Warranty INSTRUCTION MANUAL 2 2 3 3 5 16 PLCM E4 Ethernet USB controller of CN...

Страница 2: ...packing Number of inputs 12V direct current 6 0 40 169 x 126 x 20 mm 300m 100 kHz 12 buffered LPT port 500 mOhm 0 24 kg 16 optoisolated 5 buffered LPT port Ethernet USB connector type USB B signal tr...

Страница 3: ...nstallation to some part of a housing The controller has also converter PWN voltage XP34 for control of frequency converter fig 2 The controller has 3 ports The first port is presented by XS3 connecto...

Страница 4: ...t 5 5 output 6 6 output 7 7 output 8 8 output 9 9 output 10 10 input 11 11 input 12 12 input 13 13 input 14 14 output 15 15 input 16 16 output 17 17 output 18 GND 19 GND 20 GND 21 GND 22 GND 23 GND 24...

Страница 5: ...ion When choosing PLCM E4 after Next pressing software installation wizard will offer to execute automatic setting of network adapter PC for correct connection to PLCM E4 fig 8 Fig 3 4 Cable type setu...

Страница 6: ...nd update internal controller software 4 After successful plug in start PLCM control option will appear in menu MACH3 PlugIn Choose this option If you see the window as it is in fig 8 and you cannot c...

Страница 7: ...dynamically assign IP addresses e g it can be a usual home network gateway for internet connection in you local network Receiving address from DHCP server we recommend to make this item active if the...

Страница 8: ...rty applies can cause delay of tasks execution in Mach3 which can lead to loosing connection with the controller You can use several network cards when testing and setting the system With help of Doub...

Страница 9: ...ct defect 3 2 If the defect is proved warranty repair is carried out 4 We do not assume any responsibility for glass electric lamps starters and expendable materials as well as 4 1 Damaged product cau...

Страница 10: ...echnical documentation and is qualified for exploitation Lot number Technical Control Department 4 7 The product which was resold by the initial buyer to the third party 4 8 The product with defects w...

Страница 11: ...onsistent technical improvement You can always download our latest versions at www purelogic ru www purelogic ru Contacts Moscow 7 495 505 63 74 Voronezh 7 473 204 51 56 149 Office 160 Leninsky avenue...

Отзывы: