TROUBLESHOOTING
Low or no residual chlorine in pool
1. Increase Output Level. This is often required seasonally with increasing
temperatures
2. Increase run time to at least 1 hour per 10° ambient temp.
3. Activate Super Chlorination mode or chemically shock pool.
4. Remove Cell from plumbing, then inspect and clean.
5. Cold water (below 50F) can cause the The Crystal Pure 3.0 ABG to stop
generating.
6. Low pH oxidizes chlorine quickly, making it difficult to maintain desired chlorine
levels. Adjust pH levels to re-balance water.
7. Warm pool water increases chlorine demand—increase Desired Output Level% or
filter run time.
8. The Crystal Pure 3.0 ABG switch in OFF position.
9.
Desired Output Level% adjustment setting is too low.
“No Flow” LED illuminated or flashing
If there is adequate flow and the LED is still on, verify that that the arrows on the flow
switch are pointing in the direction of flow.
Low Salt / High Salt LED is on:
Verify salinity and Cell Version in the status Menu, if this doesn
’
t work, ensure correct
connection, clean cell if necessary.
Replace the new cell
Remove and inspect the cell for scale. If the cell is scaled, follow the directions on page
12 for cell cleaning. If the pool has the proper amount of salt and the LOW SALT LED
is still illuminated, the cell may be depleted and needs to be replaced.
Water leak
Ensure O-Rings are clean and in good condition.
Inspect threads for damage, ensure that each will screw back on without resistance.
No Power
Check fuses on the Control Module.
Have a professional test the input power, ensure correct wiring configuration &
connections. Make sure 120V AC input power is connected to the control
Содержание Crystal Pure 3.0 ABG
Страница 1: ...SALT CHLORINATOR FOR ABOVE GROUND POOLS Crystal Pure 3 0 ABG rystal Pure 3 0 ABG...