10.3 8,000 & 16,000 Hour Maintenance
Under typical operating conditions:
8,000 hours of run time will occur between one (1) and two (2) years of use.
16,000 hours of run time will occur between two (2) and three (3) years of use.
This will be identified by a Compressor Total Hour Alarm on the display for either
System 1 or System 2
(section 8.5.8 )
.
MODEL:
P6500W
LOCATION
NAME:
SERIAL NUMBER:
ADDRESS:
DATE INSTALLED:
Maintenance Interval (Hours)
Procedure Section
8,000
16,000 24,000 32,000 40,000
Install 8,000 Hour Maintenance Kit
P011813
11.6
Install 16,000 Hour Maintenance Kit
P011814
11.6
Read & Record Flow Rate (
FLOW
)
8.4.5.1
Measure & Record
Compressor 1 Amp Draw
9.2
Measure & Record
Compressor 2 Amp Draw
9.2
Set System Pressure (50 PSI)
8.11
Set Static Pressure (17 PSI)
8.12
Set Outlet Pressure
8.13
Test Consistent Heatless Dryer Cycling
9.6
Test Compressor ON/OFF Cycling
9.11
Test Air Fittings for Leaks
9.16
Reset Total Hour Readings to Zero
System 1 & System 2
8.6.7 &
8.6.8
Visually Inspect Inside & Outside of Unit for Loose
Wiring or Hardware
Maintenance Performed by:
Date of Maintenance:
NOTE: