![Puregas P6500W Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/puregas/p6500w/p6500w_user-manual_1627332047.webp)
PUREGAS, LLC
P6500W Air Dryer User’s Guide
Page 47 of 88
P010452 – Rev. Q
9.4 Measuring Incoming Voltage
9.4.1
Remove Top Cover (see section 8.7.1 )
9.4.2
Locate the Main POWER
Circuit Breaker.
9.4.3
Place Voltmeter probes
between the Circuit Breaker
and terminal insulation so that
they touch the metal contacts.
The voltage should measure
210 - 230 VAC
.
9.4.4
Reinstall Top Cover.
If the incoming voltage measures less than 210 VAC, it is necessary to engage the
Boost Transformer in order to increase the voltage to the desired range of 210-
230 VAC. See section 8.14 for procedure.
WARNING!
Extreme care should be exercised to avoid contact with live
electrical circuits.
It is highly recommended that you remove all
jewelry before performing any procedures.