P4200PM / P5000PM Remote Air Dryer User’s Guide
Page 43 of 79
P012649 – Rev B
9.10 Testing Cabinet Heater
NOTE:
To test the heater, the cabinet temperature must be below 40
O
F.
9.10.1
Open Front Door (section 8.4.1).
9.10.2
Power the air dryer
OFF
(section 8.3).
9.10.3
Depressurize the air dryer (section 8.4).
9.10.4
Slide out Compressor Tray (section 8.5).
9.10.5
Locate the power lead wires
to the Heater. Wire #s 9 &
21.
9.10.6
Power the air dryer
ON
(section 8.3).
9.10.7
Use a Voltmeter to measure
the voltage:
9.10.7.1
Probe the terminal
connections on the
heater sensor.
The voltage should measure
110 - 125 VAC
.
9.10.8
Power the air dryer
OFF
(section 8.3).
9.10.9
Slide in Compressor Tray.
9.10.10
Power the air dryer
ON
(section 8.3).
9.10.11
Close Front Door.