PUREGAS, LLC
P4200PM / P5000PM Remote Air Dryer User’s Guide
Page 35 of 79
P012649 – Rev B
9.3.6
Use a Voltmeter to measure
the voltage:
9.3.6.1
Place the probes in the
openings of wire #s 3
and 4 of the power
connector.
The voltage should measure
110 - 125 VAC
.
9.3.7
Slide in Compressor Tray.
9.3.8
Close Front Door.
9.4 Measuring Incoming Voltage
9.4.1
Open Front Door (section 8.4.1).
9.4.2
Lower Front Panel (section 8.4.2).
9.4.3
Locate the
POWER
Circuit
Breaker inside the front panel
of the air dryer.
WARNING!
Extreme care should be exercised to avoid contact with live
electrical circuits.
It is highly recommended that you remove all
jewelry before performing any procedures.