P4200PM / P5000PM Remote Air Dryer User’s Guide
Page 36 of 79
P012649 – Rev B
9.4.4
Use a Voltmeter to measure
the voltage:
9.4.4.1
Place the probes
between the Circuit
Breaker and terminal
insulation so that they
touch the metal
contacts.
The voltage should measure
110 - 125 VAC
.
9.4.5
Close Front Panel.
9.4.6
Close Front Door.
If the incoming voltage measures less than 110 VAC, it is recommended that steps
be taken at your facility to increase the power to the recommended level of 110-
125 VAC.
9.5 Measuring Voltages at Solid State Relay
9.5.1
Open Front Door (section 8.4.1).
9.5.2
Open Front Panel (section 8.4.2).
9.5.3
Locate the Solid State Relay
inside the front panel of the
air dryer.