PUREGAS, LLC
P4200PM / P5000PM Remote Air Dryer User’s Guide
Page 33 of 79
P012649 – Rev B
9.2 Measuring Compressor Amp Draw
9.2.1
Open Front Door (section 8.4.1).
9.2.2
Slide out Compressor Tray (section 8.5).
With the Compressor running:
9.2.3
Locate the BLACK wire (#3)
coming directly from the
compressor.
9.2.4
Use an Amp Meter to
measure the running amps.
With the compressor running, the
running amps should measure
11.0 amps or below (P4200PM)
or
15.0 amps or below (P5000PM)
9.2.5
Slide in Compressor Tray.
9.2.6
Close Front Door.
If the compressor measures over stated running amps, see section 13.11 for
troubleshooting information.
WARNING!
Internal surfaces may be hot
. Use care when coming into contact
with internal components as there is a potential for some these
components to become hot when in operation or standby.