PUREGAS, LLC
P200W2 Series Dehydrator User’s Guide
Page 75 of 82
P012213 – Rev. F
11.12 Duty Cycle Alarm
Possible Cause
Check
Corrective Action
Air leaks in pressurized
system
Verify that air supply
line and waveguide have
no leaks.
Repair or seal all air
leaks.
11.13 Can’t Create a Duty Cycle Alarm
Possible Cause
Check
Corrective Action
Duty Cycle Alarm set
point higher than default
setting of 50%
Verify Duty Cycle
Alarm set point
(Section 8.8.12 )
Adjust Duty Cycle
Alarm set point to 50%
(Section 8.8.12 )
Defective Dehydrator
Verify
DUTY CYCLE
reading is higher than
the Duty Cycle Alarm
set point (Sections
8.4.5.2 & 8.8.12 )
Contact PUREGAS
Technical Support
(Section 11.16 )
11.14 Unable to connect via Web Browser
Possible Cause
Check
Corrective Action
Dehydrator is powered
OFF
Power the Dehydrator
ON
(Section 8.3 )
Loose or defective IP
Cable
Verify IP Cable
connections (Section
8.11 )
Replace or reconnect IP
Cable (Section 8.11 )
Incorrect Network
Settings
Verify Network Settings
on front panel display
(Section 8.9 )
Use current Network
Settings or change
Network Settings locally
at the front panel display
(Section 8.9 )
Using incompatible web
browser
Use Internet Explorer
(6.0 or newer) or
Mozilla Firefox Web
Browser
Computer is not on the
same network as the
Dehydrator
Verify the computer
network
Connect computer to
same network as
Dehydrator