PUREGAS, LLC
P200W2 Series Dehydrator User’s Guide
Page 74 of 82
P012213 – Rev. F
11.8 Can’t Create a Low Pressure Alarm
Possible Cause
Check
Corrective Action
Low Pressure Alarm set
point lower than default
setting
Verify Low Pressure
Alarm set point
(Section 8.8.4 )
Adjust Low Pressure
Setting so that the
PRESSURE
reading
drops below verified set
point (Section 8.7.5 )
Defective Pressure
control
Verify that the Pressure
cannot be adjusted
(Section 8.7.5 )
Contact PUREGAS
Technical Support
(Section 11.16 )
Defective Dehydrator
Verify
PRESSURE
reading is lower than the
Low Pressure Alarm set
point (Sections 8.4.5.2
& 8.8.4 )
Contact PUREGAS
Technical Support
(Section 11.16 )
11.9 High Humidity
Possible Cause
Check
Corrective Action
High Humidity Alarm
set point too low
Verify High Humidity
Alarm set point
(Section 8.8.10 )
Raise Humidity Alarm
set point
(Section 8.8.10 )
Over 10% not
recommended
Defective Dehydrator
Humidity Alarm does
not clear within 8 hours
of first appearing
Contact PUREGAS
Technical Support
(Section 11.16 )
11.10 High Cabinet Temperature Alarm
Possible Cause
Check
Corrective Action
High Ambient
Temperature
Verify temperature of
Dehydrator operating
location. Recommended
ambient temperature is
5°-30°C (optimal)
Lower ambient
temperature of
Dehydrator operating
location
11.11 Low Cabinet Temperature Alarm
Possible Cause
Check
Corrective Action
Low Ambient
Temperature
Verify temperature of
Dehydrator operating
location. Recommended
ambient temperature is
5°-30°C (optimal)
Raise ambient
temperature of
Dehydrator operating
location