WARNING

: Servicing unit may expose hazardous live parts. Disconnect power before 

proceeding.  

CAUTION: 

EXERCISE USUAL PRECAUTIONS WHEN WORKING WITH HIGH VOLTAGE. WHEN THE 

CIRCUIT HAS BEEN D-ENERGIZED, ALWAYS DISCHARGE ANY RESIDUAL CURRENT IN THE 
SECONDARY WITH AN INSULATED HANDLE SCREW DRIVER. ALWAYS GROUND POWER SUPPLY 
AND IONIZING COLLECTING CELL WHEN BENCH TESTING. 

REFERENCE TROUBLE CHART 

SYMPTOM 

PROBABLE LOCATION 

POSSIBLE CAUSE 

CORRECTION 

Power On/Off Light 

(Amber) Out 

Primary Wiring 

No power from service 
connection to power 
supply. 

Obtain power 

Loose wiring or 
defective wiring 

Repair / Replace 

Power Indicating Light 

Defective Light 

Replace 

Cracking Noise 

 

Constant or Repeated 

Cell 

Loose Ionizing Wire 

Replace 

Dirty Cell 

Wash 

Damaged (bent) Plates 

Straighten 

Damaged (bent) ionizer 
wire holder 

Replace 

Loud Hissing Noise 

Cell 

Dirty Cell 

Wash 

High Voltage 

Loose High Voltage 
Connection 

Correct 

High Voltage 

Insufficient Ground 

Correct 

Radio and/or TV 

Interference 

Cell 

Improper Ground 

Correct 

High Voltage 

Loose High Voltage 

Correct 

 

 

 

 

 

 