ELECTRICAL WIRING  

The electrical access panel is located on the 
air cleaner cabinet assembly. Knockouts are 
provided in the top of the housing assembly. 
Wire the unit to a 120-volt, 60 HZ, 1 phase.  

Field wiring requires connecting black and 

white leads to corresponding house current 
input. Connect incoming ground (green) wire 
to the ground screw located in air cleaner. See 
Fig. 6. 

SYSTEM CHECKOUT 

After assembling and installing the unit, 

switch the control switch to ON. The on/off 
light should now be on. The light shows unit 
has line voltage. Open cell access door. The 
on/off light should go out. The blower should 
also stop. 

The CA-1000 is provided with a 3-speed 

blower switch. Set switch to speed for desired 
air flow. 

REGULAR MAINTENANCE  

Periodically the dirt collected by your unit 

must be removed. The frequency of washing will depend on the amount of dirt present in the 
air in your application.  

The washing frequency best suited for your unit can be determined by examin-ing the collector 

cells at 2-week intervals. As the dirt begins to collect, you will notice a light film, then a very 
definite build-up will be evident at a later inspection. When there is a noticeable amount of 
dirt, collecting cell must be washed.  In most areas the collection cell should be washed about 
every 12 weeks. 