ELECTRICAL WIRING
The electrical access panel is located on the
air cleaner cabinet assembly. Knockouts are
provided in the top of the housing assembly.
Wire the unit to a 120-volt, 60 HZ, 1 phase.
Field wiring requires connecting black and
white leads to corresponding house current
input. Connect incoming ground (green) wire
to the ground screw located in air cleaner. See
Fig. 6.
SYSTEM CHECKOUT
After assembling and installing the unit,
switch the control switch to ON. The on/off
light should now be on. The light shows unit
has line voltage. Open cell access door. The
on/off light should go out. The blower should
also stop.
The CA-1000 is provided with a 3-speed
blower switch. Set switch to speed for desired
air flow.
REGULAR MAINTENANCE
Periodically the dirt collected by your unit
must be removed. The frequency of washing will depend on the amount of dirt present in the
air in your application.
The washing frequency best suited for your unit can be determined by examin-ing the collector
cells at 2-week intervals. As the dirt begins to collect, you will notice a light film, then a very
definite build-up will be evident at a later inspection. When there is a noticeable amount of
dirt, collecting cell must be washed. In most areas the collection cell should be washed about
every 12 weeks.