CLEANAIR CA-1000 ELECTRONIC AIR CLEANER
READ AND SAVE THESE INSTRUCTIONS
It is highly recommended that a licensed electrician or licensed contractor install these units.
This manual contains information for location, installation, operation and service. Before
installation and operation of the air cleaner, read instructions carefully to ensure safe and
effective operation of this unit, and avoid unnecessary service cost.
Carefully unpack unit and check for damage incurred in shipment. Report any damage to freight
line immediately.
Proper installation procedures for both T-BAR ceiling and flush mount installation are provided.
Follow method that best suites application for air cleaner.
The unit cover is hinged, to allow for easy access
and serviceability of the air cleaner components.
Two (2) spring latches are located on front of cover
as shown in Fig. l. To gain access to inside of air
cleaner unit for installation and servicing, depress
both latches simultaneously and swing cover open.
T-BAR INSTALLATION
Installation requires a 10” clearance between permanent ceiling and T
-Bar ceiling. CAUTION:
Do not install unit in a T-Bar ceiling unless unit can be secured to a permanent ceiling or ceiling
joists, as described.
Installer must provide the following items for securing unit:
•
Four (4) 1/4-
20 x 1” Eyebolts
•
Four (4) 1/4-20 Hex Nuts
•
Four (4) 1/4 Flat Washers
•
Length required - 2/0 Chain
Open unit cover and remove cell assembly. (It is
necessary to remove thumb nut in the housing to
allow cell to slide into position for removal.) Install
eyebolts in cabinet top as shown in Fig. 2.