background image

WHAT THE HEPA, ULTRAVIOLET LIGHT & 

PHOTO CATALYTIC AIR CLEANER DOES 

The  Console  HEPA,  Ultraviolet  Light  &  Photo 

Catalytic Air Cleaner has been designed to remove 

particulate  such  as  atmospheric  and  household 

dust, coal dust, insecticide dust, mites, pollen, mold 

spores,  fungi,  bacteria,  viruses,  pet  dander,  wood 

smoke, cooking smoke and grease, tobacco smoke 

and more.  
The  two  non-ozone  producing,  high  output 

Ultraviolet lamps provide germicidal sterilization for 

bacteria,  viruses,  mold  and  fungi  and  provide 

photons to the CinQuartz™ Media (Photo Catalytic 

Oxidation  Filter)  to  reduce  odors  and  Volatile 

Organic Compounds (VOC’s).  
A  Final  Filter  containing  a  mixture  of  Carbon  and 

Potassium  Permanganate  further  reduces  odors, 

light and non-organic gases. 

BENEFITS 

 

Helps provide relief from allergies, asthma, and 

other respiratory illness. 

 

Kills  or  inhibits  bacteria,  viruses,  mold,  fungi 

and microbial growth. 

 

Eliminates or reduces odors and gases emitted 

from  air  fresheners,  carpets,  construction 

materials,  glues,  household  cleaners,  paints, 

varnishes, personal care products, press board 

furniture and lots more. 

 

Helps 

reduce 

housekeeping 

time 

and 

redecorating costs. 

 

Provides  a  healthier,  more  comfortable 

environment, year-round. 

 

HOW IT WORKS 

Millions  of  airborne  pollutants  are  carried  the  Air 

Cleaner by a powerful variable speed motor where 

they passes through a 5-stage filtration system. 
The  air  passes  through  a  pleated  Carbon  Prefilter 

to  remove  lint,  large  particles  and  heavy  weight 

gases  to  extend  the  life  of  the  HEPA  and  PCO 

filter. 
Smaller  particles  then  pass  through  a  long-life, 

99.97%  HEPA  (High  Efficiency  Particulate  Air) 

Media  Filter  which  captures  particles  0.3  micron 

(1/84,000 of an inch) and larger. The filter becomes 

more efficient as it gets dirtier with time. This HEPA 

filter  has  more  than  40  ft²  of  collection  surface 

area. 
The clean air passes through a reflection chamber 

where  two  High  Output  Ultraviolet  (C  band) 

Germicidal  Lamps  emit  powerful  UVC  light  rays 

which  are  designed  to  kill  or  inhibit  bacteria, 

viruses,  mold,  fungi  and  microbial  growth.  These 

are  non-ozone  producing  lamps.  The  Ultraviolet 

Light  is  also  used  to  activate  the  unique 

CinQuartz™ Media located below the UVC lamps. 
The  CinQuartz™  Photo  Catalytic  Oxidation  (PCO) 

Filter  is  a  Quartz  media  coated  with  nanoparticles 

of Titanium Dioxide (TiO

2

). The combined action of 

the  UVC  light  and  the  TiO

2

  decomposes  organic 

materials  into  basic  molecules  such  as  H

2

O  and 

CO

2

 and reduces odors and VOC’s as a result. 

Air then passes through a Final Filter containing a 

mixture  of  Carbon  and  Potassium  Permanganate 

further reducing odors and light gases. 
Clean air is discharged back into the room. 

 

OPERATING INSTRUCTIONS 

Lean Air Cleaner on side panel and pull out of box.  

If your unit has any signs of damage, immediately 

contact  the  store  where  the  Air  Cleaner  was 

purchased. 
Keep  the  shipping  carton  and  packaging  in  case 

the need arises to store or transport the unit. 
Remove  all  packaging  from  the  unit.  Choose  a 

suitable  location  to  allow  unobstructed  circulation 

from the sides and back of the unit. If unit has to be 

placed against a wall, allow at least 6-8 inches (15-

20 cm) for circulation. 
The  Air  Cleaner  plugs  into  a  regular  outlet  at  the 

voltage shown on rating label. 
The Control Switch for the Air Cleaner is located on 

the right side. To turn the Air Cleaner on, rotate the 

Control  Switch  knob  clockwise.  This  controls  the 

power  to  the  Fan  and  to  the  UVC  Lamps.    When 

the    Control  Switch  is  turned  just  past  the  click 

position,  the  fan  is  on  high  speed.  Rotating  the 

Control  Switch  completely  clockwise  reduces  the 

fan  speed  to  it’s  lowest  setting.  When  the  Control 

Switch is turned ON, the Indicator on the front  will 

be illuminated.

 

The  Air  Cleaner  is  designed  to  run  continuously 

to provide clean, filtered air 24 hours a day.  

Running  the  Air  Cleaner  intermittently  will 

shorten the effective life of the lamps. 
Note:  Do  not  allow  the  cord  to  be  placed 

where it  may be walked on or allow anything to 

roll over it. 

WARNING  

This unit is designed to emit powerful ultraviolet radiation 

to  sterilize  microorganisms.  It  is  dangerous  to  come  in 

contact  with  or  look  at  the  light  from  this  unit.  Always 

turn  the  Air  Cleaner 

OFF

  and 

UNPLUG

  the  unit  before 

opening panels or the lamp access door. 

WARNING  

The  air  cleaner  has  been  shipped  without  the  2  UVC 

lamps installed. The filters are enclosed in plastic bags. 

Before  running  the  unit  remove  the  plastic  bags  and 

discard  safely.  Install  the  lamps  following  the 

instructions given in the maintenance instructions. Use 

the cotton gloves provided when handling the lamps.  

Содержание PD-900C

Страница 1: ... HEPA Filter Two High Output Ultraviolet Germicidal Lamps CinQuartz Photo Catalytic Oxidation Filter removes unpleasant odors and Volatile Organic Compounds Carbon Potassium Permanganate Final Filter removes non organic gases Kills or inhibits bacteria viruses mold fungi and microbial growth Easy to change filters and lamps Powerful Variable Speed motor delivers up to 250 CFM of clean sterilized a...

Страница 2: ...s The CinQuartz Photo Catalytic Oxidation PCO Filter is a Quartz media coated with nanoparticles of Titanium Dioxide TiO2 The combined action of the UVC light and the TiO2 decomposes organic materials into basic molecules such as H2O and CO2 and reduces odors and VOC s as a result Air then passes through a Final Filter containing a mixture of Carbon and Potassium Permanganate further reducing odor...

Страница 3: ...s will shorten the life expectancy of the HEPA filter Note Handle the HEPA filter by the frame only The paper is fragile and a puncture or tear will reduce efficiency Replacing the UVC Lamps PCO Filter and Final Filter 1 To change the PCO filter Final filter and UVC lamps turn the Air Cleaner OFF and UNPLUG it Remove the screws from the lamp access panel and remove the panel DO NOT misplace the pa...

Страница 4: ...ter 2 carbon potassium permanganate final filters gloves 4 WARNING Eye and skin damage may result from direct exposure to the light produced by the lamps used in this product Make sure the Air Cleaner is OFF and UNPLUGGED before the lamp access panel is open CAUTION Do not touch the lamp glass with bare hands Always use the gloves provided when installing the lamps The oil from your hands may redu...

Страница 5: ...us voltage or other hazards Refer all servicing to qualified personnel 6 Never push objects of any kind into the Air Cleaner through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock 7 If the Air Cleaner has been dropped or the cabinet has been damaged unplug the unit from the wall outlet and refer servicing to qualified servi...

Страница 6: ...either defective parts or replacement parts LIMITATIONS OF WARRANTY All implied warranties including implied warranties of merchantability are hereby limited in duration to the period for which the limited warranty is given The expressed warranties made in this warranty are exclusive and may not be altered enlarged or changed by any distributor dealer or other person whatsoever PUR DISTRIBUTION LT...

Страница 7: ......

Страница 8: ...VE PLASTIC PACKAGING ON INSIDE FILTERS ENLEVER LA PELLICULE DE PLASTIQUE DES FILTRES REFER TO OWNER S MANUAL FOR INSTALLATION INSTRUCTIONS VOIR LES DIRECTIVES DANS LE MANUEL D INSTALLATION QUESTIONS DES QUESTIONS CALL APPELEZ 416 410 3450 ...

Отзывы: