SERVICE INSTRUCTION
P 601 - P 3001
P 601/701/801/1001/1501/2001/3001.58.0308.Eng/Digital
6 (22)
Complete overhaul
A complete overhaul of the pump should be carried out if there has
been water or oil in the motor housing, or if the pump has been in daily
operation for one year or 2000 operating hours. At low utilization the
pumps overhaul intervals can be extended.
Dismantle the pump completely, replace damaged and worn parts.
Clean all sealing surfaces and check that they are not damaged. If
water or oil has leaked into the motor housing, inspect and replace
ball bearings and shaft seals as required.
Warning
Prior to any work being carried out, always check that the pump is
disconnected from the power supply, and cannot be energized.
Dismantling
Loosen the bottom nuts/screws and remove the base plate. Unscrew
the nuts for the diffuser. Remove outer casing and diffuser with a crow
bar applied between diffuser and impeller nut. Pull out the diffuser
from the outer casing.
Unscrew the oil plug and drain the oil into a clean can and inspect it.
Check the oil. See
maintenance
of Shaft Seals.