SERVICE INSTRUCTION
P 601 - P 3001
P 601/701/801/1001/1501/2001/3001.58.0308.Eng/Digital
17 (22)
Testing
Connect power cable to power supply and start the pump. Check
the direction of rotation. Seen from above, the pump should make a
counter-clockwise jerk.
If possible, operate the pump in water and measure the head against
a PSI gauge. Measure the PSI and use formula-Feet = PSI X 2.31
Check against pump curve, it should be close to max lift.
Содержание P 1001