SERVICE INSTRUCTION
P 601 - P 3001
P 601/701/801/1001/1501/2001/3001.58.0308.Eng/Digital
12 (22)
Note!!
Locate the holes for the terminal cables in the housing about 4
inches from the exit of the cable groups on the winding head.
When the housing has been mounted it may be cooled with compressed
air. When the housing has cooled down, the terminal cables can be
pulled up through the holes in the housing with a hook made of steel
wire. Mount the cable bushings (6-hole seals) on the two groups of
cables.
The thermal switches are connected in series and the connections
should be well insulated.
Assembly
Prior to assembly, clean all parts carefully, especially 0-ring grooves
and mating surfaces.
Grease or oil 0-rings to eliminate damage during assembly. Lubricate
screw threads to protect them and to simplify future disassembly.
Stator Unit, Contactor and Main Cover
Grease and mount the 0-ring in the upper bearing seat. Connect all
stator leads to the contactor according to wiring diagram and mount
the contactor at the bottom of the contactor chamber to the mounting
rail.
Grease and mount the 0-ring between stator unit and main cover.
Mount the main cover on the housing and tighten it against the stator
housing with the nuts. Check that the 0-ring or stator leads have not
been jammed.
Содержание P 1001