SERVICE INSTRUCTION
P 601 - P 3001
P 601/701/801/1001/1501/2001/3001.58.0308.Eng/Digital
10 (22)
Cover and Cable Gland
Unscrew the cap nuts for the cover. Lift off the cover and disconnect
the cable from the contactor (3-phase units only).
If water has penetrated through the cable gland, the cable seal should
be replaced. Remove strain relief clamp prior to unscrewing cable
gland body. Pull out cable, rubber bushing and washers.
NOTE!!
It is very important that the replacement parts be correctly
sized for the cable. Incorrect sizing can cause severe damage to the
pump.
Stator Unit with Contactor
Unscrew the nuts for main cover and remove the main cover from the
stator unit.
The motor insulation should always be tested in connection with
service or repair. Measure insulation resistance between the different
phase windings, between windings and ground, and between win-
dings and thermal switch circuit. The insulation resistance should be
measured with 500 V megohm-meter, and the reading should be at
least I megaohm. If the reading is lower, but not completely open,
drying the stator may recover usage of the motor.
If insulation resistance test shows motor open, the stator unit should
be rewound, or replaced.