6 (15)
SERVICE INSTRUCTION
K 152, 202, 203, 252, 302
K152/202/203/252/302.58.0101.Eng/Digital
RemovaI of Mechanical
Shaft Seal Unit
Remove the three (3) screws holding the seal unit to the oil
housing bottom. The seal unit flange is provided with two (2)
threaded holes. Clean the holes with a small screw driver (or tap
M 6).
Remove seal unit by using two M 6 screws, approximately 40 mm
in length, fitted into the threaded holes. By turning the screws
evenly the seal unit will back off from the oil housing bottom.
A defective seal unit should always be replaced. The defective
seal unit should be sent to the nearest service point in ex-
change for a rebuilt unit.
Removal of Stator Unit
Place the motor unit in an upright position. Remove the screws
holding the stator housing and oil housing together. Remove the
two (2) plastic caps and screw two screws M 12 into the threa-
ded holes.
Tighten the screws to separate stator housing and oil housing.
The stator unit can now be lifted away from the oil housing and
shaft-/rotor unit. If stator unit doesn’t separate, tap oil housing
gently with a soft hammer.