5
SETTING UP A DMX SERIAL DATA LINK
•
Connect the (male) 3-pin connector side of
the DMX cable to the output (female) 3-pin
connector of the controller.
•
Connect the end of the cable coming from
the controller, which will have a (female) 3-pin
connector, to the input connecotr of the next
fixture consisting of (male) 3-pin connector.
•
Then proceed to connect from the output
as stated above to the input of the following
fixture and so on.
MASTER/SLAVE FIXTURE LINKING
•
Connect the (male) 3-pin connector side of the DMX cable to the output (female)
3-pin connector of the first fixture.
•
Connect the end of the cable coming from the first fixture, which will have a
(female) 3-pin connector, to the input connector of the next fixture consisting of a
(male) 3-pin connector.
•
Then proceed to connect from the output as stated above to the input of the
following fixture and so on.
•
Often, the setup for Master-Slave and Standalone operation requires that the first
fixture in the chain is initialised for this purpose via either the settings in the control
panel, or DIP switches.
•
Secondly, the fixtures that follow may also require a slave setting. See “Operating
Instructions” on page 6 for guidance on this type of setup.
MOUNTING
Orientation:
•
This fixture may be mounted on a suitable base in any position provided there is
adequate room for ventilation.