USER CONFIGURATION

SERVICE FUNCTIONS
To reset the unit:

• 

Press the 

MENU

 button until the display shows “rSet”. Press 

ENTER

 to confirm.

To test the operating functions:

• 

Press 

MENU

 until “teSt” is displayed and the sequece will commence.

OPERATION MODE

• 

Press the 

MENU

 button and the display shows each option in sequence, then 

press 

ENTER

 and the LCD will show modes for you to choose.

• 

Use the 

UP

/

DOWN

 buttons to set the desired inversion, then press 

ENTER

 to 

confirm.

To set the DMX channel configuration:

• 

Press the 

MENU

 button until it shows “ChNd”, then press 

ENTER

 and the LCD will 

show “16CH” or “21CH”.

• 

Use the 

UP

/

DOWN

 buttons to set the desired channel mode and press 

ENTER

 to 

confirm.

• 

Choose a unit to function as the Master, then select one of the modes as an auto 

running programme.

• 

Finally, chain the units together using DMX cable, the required speed mode can be 

the Master one’s programming. The other units are set to the same DMX Address.

Set Master/Slave Mode:

• 

Press MODE until “SlNd” is displayed,

• 

Press ENTER to chose “master”, “slave 1” or “Slave 2” modes, Press ENTER to 

set the mode. This mode will allow you to link up to 32 units together without a 

controller.

• 

Use standard DMX cables to daisy chain your units together via the DMX 

connector on the rear of the units.

• 

Proper performance it may be necessary to use a terminator at the last fixture.

AUTO Speed Mode:

• 

This mode allows a single unit to run one of four factory installed programme in a 

range of 9 speeds.

Sound Mode:

• 

Press

 MODE 

until “SeNs” is displayed.

 

Press 

ENTER 

to choose sensitivity of response by use of the 

UP

 and 

DOWN

 

buttons. Press 

ENTER

 to set the desired level.

To set the PAN to inverting or non-inverting:

• 

Press the 

MODE

 button until it shows “PaN”, then press 

ENTER

 and the LCD will 

show “OFF” or “ON”.

• 

Use the 

UP

/

DOWN

 buttons to set the desired mode and press 

ENTER

 to confirm.

To set the Tilt to inverting or non-inverting:

• 

Press the 

MODE 

button until it shows “TiLt”, then press 

ENTER

 and the LCD will 

show “OFF” or “ON”.

• 

Use the 

UP

/

DOWN

 buttons to set the desired mode and press 

ENTER

 to confirm.

LED Mode:

• 

Press

 MODE 

until “Led” is displayed.

 

Press 

ENTER

 and then use the 

UP

/

DOWN

 buttons to set “ON” or “OFF” The LED 

display will turn off after a time unless a button is pressed.

Содержание IMPSTAR 40

Страница 1: ...1 Model Impstar 40 LED Moving Wash Beam Light with Halo...

Страница 2: ...Safety Information for Installation and Operation When installing make sure that the product is not exposed to extreme heat moisture or dust If you re using a smoke machine make sure that the product...

Страница 3: ...ermines the number of fixtures the data link can support Important Fixtures on a serial data link must be daisy chained in one single line To comply with the EIA 485 standard no more than 32 devices s...

Страница 4: ...nductor 3 pin female output 5 pin male input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Termination reduces signal errors To avoid signal transmission problems and inter...

Страница 5: ...fixture Connect the end of the cable coming from the first fixture which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector Then proceed...

Страница 6: ...splay shows the menu item that you have selected When a menu item is selected the display will show immediately the first available option for the selected menu function To select a menu item press EN...

Страница 7: ...7 SoUn 1 4 AuTo on Off 0 100 on off no YES no YES YES SeNs Led DiSp Pan Tilt no Test Hour vEr rSEt Performs mode test sequence Displays hours usage Displays software version Resets to default...

Страница 8: ...master slave 1 or Slave 2 modes Press ENTER to set the mode This mode will allow you to link up to 32 units together without a controller Use standard DMX cables to daisy chain your units together vi...

Страница 9: ...0 3 000 255 Pan Tilt Speed from fast to slow 4 000 255 LED Dimmer0 100 5 000 008 No function 009 255 LED Strobe slow to fast 6 000 255 RED LED Dimmer0 100 7 000 255 Green LED Dimmer0 100 8 000 255 Blu...

Страница 10: ...n 011 044 5050 SMD section 4 Red 045 079 5050 SMD section 4 Green 080 114 5050 SMD section 4 Blue 115 149 5050 SMD section 4 Red mix Green 150 184 5050 SMD section 4 Red mix Blue 185 219 5050 SMD sect...

Страница 11: ...mix Blue 220 255 5050 SMD section 1 RGB 18 000 010 No Function 011 044 5050 SMD section 2 Red 045 079 5050 SMD section 2 Green 080 114 5050 SMD section 2 Blue 115 149 5050 SMD section 2 Red mix Green...

Страница 12: ...ft lint free moistened cloth Do not use any chemicals abrasives or solvents that could damage the device There are no user serviceable parts in this product Refer all servicing to qualified personnel...