1.4. Specifications.
- electrical parameters (tab.2)
- mechanical parameters (tab.3)
- operation safety (tab.4)
- operating parameters (tab.5)
Electrical parameters (tab. 2).
Mains supply
176÷264V AC
Current up to
1,3A@230V AC max.
Supply power
241W max.
Efficiency
82%
Output voltage
AUX1÷AUX16 - cameras
Output voltage DVR - recorder
11V ÷ 13,8V DC – buffer operation
9,5V ÷ 13,8V DC – battery-assisted operation
12V DC
– maintained regardless of the state of battery charge
Output current
16 x 0,75A + 4A re 2A battery charge
Ripple
120 mV p-p max.
Battery charge current
(batteries 1x17Ah/ 1x28Ah/ 1x40Ah/ 1x65Ah)
2A max. (+/-5%)
Short-circuit protection SCP
cameras: 16 x PTC 1A, polymer fuse
recorder: 1 x F 4A, glass fuse
Overload protection OLP
Current consumption by PSU systems
105% ÷ 150% of the PSU power, automatic return
0,33A
Overvoltage protection OVP
>16V (activation requires disconnecting the load or supply for
about 20s.)
Battery circuit protection SCP and reverse
polarity connection
glass fuse 30A
Surge protection
varistors
Excessive discharge protection UVP
U<9,5V (+/-5%)
– disconnect of connection battery
Optical indication of operation:
LED: AC, DC, TEMP, LoB, ALARM, AUX1÷AUX16
Acoustic operation indication:
Piezoelectric indicator ~75dB/0,3m
The ALARM technical output of collective failure
Relay type: 1A@ 30VDC/50VAC
The
F
MAINS
fuse in the 230V power supply circuit
T 6,3A
F
DVR
fuse in the recorder power supply circuits
F 4A
Mechanical parameters (tab. 3).
Enclosure dimensions
W=19”, H=2U; 482 x 88 x 223 mm (WxHxD)
Fixation
four-point butt mounting to RACK profiles
– the set include 4 M6 cage nuts
Net weight
6,20kg / 6,60kg
Enclosure
Steel plate RAL 9005, black
Connectors
230V AC input: the IEC C14 socket with a fuse, power cable 2m
(included)
Outputs:
ALARM, AUX1÷AUX16: Φ0,5-2,1 (AWG 24-12) 0,5-1,5mm
2
Output DVR
: Φ0,5-2,1 (AWG 24-12) 0,5-1,5mm
2
, power cable 2m (included)
Battery output BAT: 6,3F-2,5
Notes
Forced cooling (fan).
Operation safety (tab.4).
Protection class PN-EN 60950-1:2007
I (first)
Protection grade PN-EN 60529: 2002 (U)
IP20
Electrical strength of insulation:
- between input and output circuits of the PSU (I/P-O/P)
- between input circuit and PE protection circuit (I/P-FG)
- between output circuit and PE protection circuit (O/P-FG)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100 MΩ, 500V/DC
Operating parameters (tab.5).
Environmental class
II
Operating temperature
-
10ºC...+45ºC
Storage temperature
-
20ºC...+60ºC
Relative humidity
20%...90%, without condensation
Vibrations during operation
unacceptable
Impulse waves during operation
unacceptable
Direct insulation
unacceptable
Vibrations and impulse waves during transport
According to PN-83/T-42106