background image

www.pulsar.pl

    

 

 

 

RUPS1612RP   

 

 

RACK POWER CCTV

 

 

CONTENTS: 
1. Technical description. 

1.1. General description 
1.2. Block diagram 
1.3. Description of PSU components and connectors 
1.4. Specifications 

2. Installation. 

2.1. Requirements 
2.2. Installation procedure 

3. Operating status indication. 

3.1. LED indication 
3.2. Technical output 
3.3. Acoustic indication 

4. Operation and use. 

4.1. Overload or short circuit of the PSU output 
4.2. Battery-assisted operation 
4.3. Maintenance 
 
 

1.  Technical description. 
 

1.1.  General description. 

     The 

RUPS1612RP

  buffer  power  supply  unit  is  designed  for  uninterrupted  power  supply  of  up  to  16  HD 

cameras requiring stabilized voltage of 

12V DC (+/- 15%). 

The PSU has two circuits: 

1x4A/12V DC

 for supplying 

the recorder and 

16x0,75A/13,8V DC

 for both cameras. Current efficiency of the PSU amounts to: 

 

Output current 16x0,75A + 4A re 2A battery charge 

Total device c battery: 18A max. 

 
     In  case  of  power  decay,  a  battery  back-up  is  activated  immediately.  The  PSU  is  fitted  with  16  outputs 

protected independently with polymer fuse PTC 1A and the output for the recorder is protected with the 4A polymer 
fuse.  The  power  supply  is  fitted  with  the  ALARM  output of  collective  failure.  In case  of  failure,  relay  contacts  are 
switched automatically,  which is accompanied by acoustic and optical indication (the corresponding  led goes on). 
The power supply construction is based on the switch mode PSU with high energy efficiency and is located in an 
enclosure adapted for mounting in standard 

RACK

 19

” cabinets.  

 

1.2.  Block diagram. 

 

 

Fig.1. The block diagram of the PSU. 

 

1.3.  Description of PSU components and connectors. 

 

Table 1. Elements of the PSU. 

Element no. 

 [Fig. 2, 3] 

Description 

 

AC

 

OK

 

– green LED, indicating the presence of 230V voltage 

 

DC

 

OK

 

– green LED, indicating the presence of DC voltage

 

 

TEMP 

– red LED, indicating too high temperature of the power supply (>70°C)

 

Содержание RUPS1612RP

Страница 1: ...RUPS1612RP v 1 0 RUPS 13 8V 12V 20A PTC RACK mounted buffer power supply for up to 16 cameras and recorder EN Edition 2 from 30 03 2017 Supercedes the edition 1 from 15 03 201 ...

Страница 2: ...ery charge current 2A batteries 1x17Ah 1x28Ah 1x40A 1x65Ah control of voltage presence at the AUX1 AUX16 outputs DVR acoustic indication of failure LED optical indication AC DC TEMP LoB ALARM AUX1 AUX16 DVR the ALARM technical output of collective failure relay type activated by 230V AC power loss low voltage of the PSU 11 5V activation of the output fuse in the camera power supply circuit activat...

Страница 3: ...A 4A recorder 2A battery charge Total device current battery 18A max In case of power decay a battery back up is activated immediately The PSU is fitted with 16 outputs protected independently with polymer fuse PTC 1A and the output for the recorder is protected with the 4A polymer fuse The power supply is fitted with the ALARM output of collective failure In case of failure relay contacts are swi...

Страница 4: ...ndependently protected outputs of the recorder BAT battery output ALARM technical output of collective failure relay BUZZER micro switch turning ON OFF of acoustic indication switch in the top position indication ON switch in the down position indication OFF FDVR glass fuses in the recorder DVR power supply circuits F4A 230V AC INPUT power socket 230V AC power cable 1 5m included FMAINS fuse in th...

Страница 5: ...RM technical output of collective failure Relay type 1A 30VDC 50VAC The FMAINS fuse in the 230V power supply circuit T 6 3A FDVR fuse in the recorder power supply circuits F 4A Mechanical parameters tab 3 Enclosure dimensions W 19 H 2U 482 x 88 x 223 mm WxHxD Fixation four point butt mounting to RACK profiles the set include 4 M6 screws cage nuts Net weight 6 20kg 6 60kg Enclosure Steel plate RAL ...

Страница 6: ...a power switch therefore an appropriate overload protection shall be guaranteed in the power supply circuit Moreover the user shall be informed about the method of unplugging usually through assigning an appropriate fuse in the fuse box The electrical system shall follow valid standards and regulations 2 2 Installation procedure 1 Before installation cut off the voltage in the 230V power supply ci...

Страница 7: ...UX16 output off no DC voltage in the AUX1 AUX16 output GREEN LED on DC voltage in the DVR output off no DC voltage in the DVR output 3 2 Technical output The power supply is fitted with the ALARM output of collective failure relay type A collective failure can be triggered by the following events 230V AC mains power failure Activation of the PTC polymer fuse in the camera power supply circuit Acti...

Страница 8: ...he PSU is equipped with the discharged battery disconnection system During the battery assisted operation reducing voltage below 9 5V at the battery terminals will cause battery disconnection 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply network The PSU does not require performing any specific maintenance measures I...

Отзывы: