background image

www.pulsar.pl

    

 

 

 

RUPS1612RP   

 

  

RACK POWER CCTV 

 

 

 

LoB 

– red LED, indicating too low battery voltage (<11,5V)

 

 

LED ALARM 

– red LED failure indication 

 

Green LED 

AUX1 ÷ AUX16 

– voltage indication at the AUX outputs 

 

LED DVR 

– 

Green LED 

voltage indication at the DVR outputs

 

 

AUX1 ÷ AUX16 

– independently protected outputs to cameras 

 

DVR 

– independently protected outputs of the recorder

 

 

BAT 

– battery output 

 

ALARM 

– technical output of collective failure – relay

 

 

BUZZER, micro switch, 

turning ON / OFF of acoustic indication 

 

switch in the top position, indication ON

 

 

switch in the down position, indication OFF

 

 

F

DVR

, glass fuses in the recorder DVR (+) power supply circuits, F4A

 

 

230V AC INPUT

, power socket 230V AC, power cable 1,5m included 

 

F

MAINS

,

 fuse in the supply circuit 230V AC, T 6,3A/250V 

 

 

 

Fig. 2. The front power of the power supply unit. 

 

 

 

Fig.3. The view of the PSU. 

 

 

Содержание RUPS1612RP

Страница 1: ...RUPS1612RP v 1 0 RUPS 13 8V 12V 20A PTC RACK mounted buffer power supply for up to 16 cameras and recorder EN Edition 2 from 30 03 2017 Supercedes the edition 1 from 15 03 201 ...

Страница 2: ...ery charge current 2A batteries 1x17Ah 1x28Ah 1x40A 1x65Ah control of voltage presence at the AUX1 AUX16 outputs DVR acoustic indication of failure LED optical indication AC DC TEMP LoB ALARM AUX1 AUX16 DVR the ALARM technical output of collective failure relay type activated by 230V AC power loss low voltage of the PSU 11 5V activation of the output fuse in the camera power supply circuit activat...

Страница 3: ...A 4A recorder 2A battery charge Total device current battery 18A max In case of power decay a battery back up is activated immediately The PSU is fitted with 16 outputs protected independently with polymer fuse PTC 1A and the output for the recorder is protected with the 4A polymer fuse The power supply is fitted with the ALARM output of collective failure In case of failure relay contacts are swi...

Страница 4: ...ndependently protected outputs of the recorder BAT battery output ALARM technical output of collective failure relay BUZZER micro switch turning ON OFF of acoustic indication switch in the top position indication ON switch in the down position indication OFF FDVR glass fuses in the recorder DVR power supply circuits F4A 230V AC INPUT power socket 230V AC power cable 1 5m included FMAINS fuse in th...

Страница 5: ...RM technical output of collective failure Relay type 1A 30VDC 50VAC The FMAINS fuse in the 230V power supply circuit T 6 3A FDVR fuse in the recorder power supply circuits F 4A Mechanical parameters tab 3 Enclosure dimensions W 19 H 2U 482 x 88 x 223 mm WxHxD Fixation four point butt mounting to RACK profiles the set include 4 M6 screws cage nuts Net weight 6 20kg 6 60kg Enclosure Steel plate RAL ...

Страница 6: ...a power switch therefore an appropriate overload protection shall be guaranteed in the power supply circuit Moreover the user shall be informed about the method of unplugging usually through assigning an appropriate fuse in the fuse box The electrical system shall follow valid standards and regulations 2 2 Installation procedure 1 Before installation cut off the voltage in the 230V power supply ci...

Страница 7: ...UX16 output off no DC voltage in the AUX1 AUX16 output GREEN LED on DC voltage in the DVR output off no DC voltage in the DVR output 3 2 Technical output The power supply is fitted with the ALARM output of collective failure relay type A collective failure can be triggered by the following events 230V AC mains power failure Activation of the PTC polymer fuse in the camera power supply circuit Acti...

Страница 8: ...he PSU is equipped with the discharged battery disconnection system During the battery assisted operation reducing voltage below 9 5V at the battery terminals will cause battery disconnection 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply network The PSU does not require performing any specific maintenance measures I...

Отзывы: