background image

www.pulsar.pl

    

 

 

 

RUPS1612RP   

 

  

RACK POWER CCTV 

 

 

3.3.  Acoustic indication. 

 

A collective failure is indicated by the piezoelectric indicator, 1 beep every second. The acoustic indication 

can be turned off by changing the ON / OFF position of the switch   . 
 

 

switch in the up position, indication ON

 

      

 

switch in the down position, indication OFF 

 

4.  Operation and use. 
 

4.1.  Overload or short circuit of the PSU output. 

   The 

AUX1 ÷ AUX16 power supply outputs are protected against by polymer fuses  PTC. In the case of 

fuse activation, disconnect  the load from the power supply output for approximately  1 minute. The DVR  output of 
the  recorder  is  protected  with  a  glass  fuse;  in  the  case  of  a  fuse  failure,  it  should  be  replaced  with  a  fuse  of  the 
same type). 

 
   4.2  Battery-assisted operation 

  In case of a main power outage, the device is immediately switched into a battery-assisted operation.  
 

 
The  PSU  is  equipped  with  the  discharged  battery  disconnection  system.  During 

the  battery-assisted  operation,  reducing  voltage  below  9,5V  at  the  battery  terminals  will 
cause battery disconnection. 

 
 

4.3  Maintenance. 

Any  and  all  maintenance  operations  may  be  performed  following  the  disconnection  of  the  PSU  from  the 

power supply network. The PSU   does not require performing any specific maintenance measures. In case of fuse 
replacement, use a replacement of the same parameters. 

 

 

 

WEEE LABEL 

 

Waste electrical and electronic equipment must not be disposed of with normal household 

waste. According to the European Union WEEE Directive, waste electrical and electronic 

equipment should be disposed of separately from normal household waste

 

 

CAUTION! 

The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but 

recycled according to the applicable law

.

 

 
 

 

 

Pulsar  

Siedlec 150,  32-744 Łapczyca, Polska 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

Содержание RUPS1612RP

Страница 1: ...RUPS1612RP v 1 0 RUPS 13 8V 12V 20A PTC RACK mounted buffer power supply for up to 16 cameras and recorder EN Edition 2 from 30 03 2017 Supercedes the edition 1 from 15 03 201 ...

Страница 2: ...ery charge current 2A batteries 1x17Ah 1x28Ah 1x40A 1x65Ah control of voltage presence at the AUX1 AUX16 outputs DVR acoustic indication of failure LED optical indication AC DC TEMP LoB ALARM AUX1 AUX16 DVR the ALARM technical output of collective failure relay type activated by 230V AC power loss low voltage of the PSU 11 5V activation of the output fuse in the camera power supply circuit activat...

Страница 3: ...A 4A recorder 2A battery charge Total device current battery 18A max In case of power decay a battery back up is activated immediately The PSU is fitted with 16 outputs protected independently with polymer fuse PTC 1A and the output for the recorder is protected with the 4A polymer fuse The power supply is fitted with the ALARM output of collective failure In case of failure relay contacts are swi...

Страница 4: ...ndependently protected outputs of the recorder BAT battery output ALARM technical output of collective failure relay BUZZER micro switch turning ON OFF of acoustic indication switch in the top position indication ON switch in the down position indication OFF FDVR glass fuses in the recorder DVR power supply circuits F4A 230V AC INPUT power socket 230V AC power cable 1 5m included FMAINS fuse in th...

Страница 5: ...RM technical output of collective failure Relay type 1A 30VDC 50VAC The FMAINS fuse in the 230V power supply circuit T 6 3A FDVR fuse in the recorder power supply circuits F 4A Mechanical parameters tab 3 Enclosure dimensions W 19 H 2U 482 x 88 x 223 mm WxHxD Fixation four point butt mounting to RACK profiles the set include 4 M6 screws cage nuts Net weight 6 20kg 6 60kg Enclosure Steel plate RAL ...

Страница 6: ...a power switch therefore an appropriate overload protection shall be guaranteed in the power supply circuit Moreover the user shall be informed about the method of unplugging usually through assigning an appropriate fuse in the fuse box The electrical system shall follow valid standards and regulations 2 2 Installation procedure 1 Before installation cut off the voltage in the 230V power supply ci...

Страница 7: ...UX16 output off no DC voltage in the AUX1 AUX16 output GREEN LED on DC voltage in the DVR output off no DC voltage in the DVR output 3 2 Technical output The power supply is fitted with the ALARM output of collective failure relay type A collective failure can be triggered by the following events 230V AC mains power failure Activation of the PTC polymer fuse in the camera power supply circuit Acti...

Страница 8: ...he PSU is equipped with the discharged battery disconnection system During the battery assisted operation reducing voltage below 9 5V at the battery terminals will cause battery disconnection 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply network The PSU does not require performing any specific maintenance measures I...

Отзывы: